General IconGeneral
BrandData Aire
ModelDAMA-02
CategoryAccessories
LanguageEnglish

Summary

Introduction to Mini Ceiling Systems

Product Information

Details on the Mini Ceiling Systems environmental control units and their capabilities.

Model Identification

Explains the nomenclature for identifying specific unit models and their configurations.

Inspection Upon Arrival

Procedures for inspecting the unit upon arrival for damage and verifying contents.

Included Paperwork

Information on essential documentation like startup sheets, warranty cards, and diagrams.

Equipment Storage Guidelines

Guidelines for short-term and long-term storage to maintain unit integrity.

Recommended Storage Room Conditions

Recommended temperature, humidity, and environmental conditions for equipment storage.

General Storage Considerations

Safety and general recommendations for storing equipment to prevent damage.

Trademarks, Copyrights, and References

Disclaimer regarding trademarks, copyrights, and references used in the manual.

Installation Procedures

Recommended Tools for Installation

Lists essential tools required for the successful installation of the unit.

Pre-Installation Steps

Steps and considerations before beginning the physical installation of the unit.

Installation Planning Considerations

Key factors to consider when planning the installation layout and process.

Room Considerations for Installation

Requirements for the installation space, including vapor barriers and air infiltration.

Equipment Handling and Rigging

Safe procedures for moving, lifting, and rigging the unit to prevent damage.

Rigging Equipment

Specific instructions related to rigging the unit safely and effectively.

Locating the Unit

Guidelines for selecting the proper placement and mounting location for the unit.

Horizontal Airflow Units

Details specific to units configured for horizontal airflow.

Installing and Mounting the Unit

Step-by-step instructions for physically mounting the unit into its final position.

Vertical Airflow Units

Details specific to units configured for vertical airflow.

Air Cooled Packaged Units

Installation specifics for packaged air-cooled units.

Indoor Condensers and Condensing Units

Installation notes for indoor condenser/condensing unit configurations.

Piping Guidelines

General guidelines and best practices for refrigerant and fluid piping.

Split Air-Cooled Unit Piping

Specific requirements and considerations for piping split air-cooled units.

Discharge Lines Installation

Instructions for installing discharge (hot gas) lines and check valves.

Liquid Lines Installation

Guidelines for sizing and installing liquid refrigerant lines.

Suction Lines Installation

Guidelines for sizing and installing suction refrigerant lines.

Recommended Line Sizing

Tables and guidance for selecting appropriate line sizes for various refrigerants.

Connection Sizes for Air-Cooled Units

Specifies connection sizes for air-cooled units.

Connection Sizes for Water;Glycol Cooled Units

Specifies connection sizes for water/glycol cooled units.

Connection Sizes for Chilled Water Units

Specifies connection sizes for chilled water units.

Field Piping: Condenser Above Evaporator

Piping configuration when the condenser is located above the evaporator.

Field Piping: Condenser Below Evaporator

Piping configuration when the condenser is located below the evaporator.

Connection Sizes for Fluid Cooler

Specifies connection sizes for fluid cooler (dry cooler) units.

Condensate Drain System

Instructions for installing condensate drain lines, traps, and pumps.

Humidifier Installation

Installation details for optional steam generator humidifiers.

Refrigerant Piping Protection

Safety measures for protecting refrigerant piping from overpressure.

Water;Glycol Cooled Unit Piping

Specifics for piping water/glycol cooled systems.

Leak Testing Procedures

Procedures and importance of thorough leak testing for system integrity.

Electrical Installation Guidelines

Guidelines for safe and correct electrical wiring and connections.

Commissioning Information

Process and steps for commissioning the installed unit.

Electrical Connections

General Electrical Field Wiring Guidelines

Best practices and safety for field electrical wiring.

Electrical Service Requirements

Verifying utility power supply and connections.

Understanding Nameplate Ratings

Using unit nameplate information for electrical requirements.

Grounding Procedures

Requirements for proper electrical grounding of the unit.

Voltage Tolerance

Acceptable voltage ranges and phase imbalance for proper operation.

Heat Exchanger Auxiliary Control Wiring

Wiring instructions for auxiliary controls on remote heat exchangers.

Remote Shutdown Setup

How to connect and use remote shutdown contacts.

Mini-dap4 Controller Overview

Features and operation of the advanced Mini-dap4 controller.

Remote Alarm Contacts

How to access and use remote alarm output contacts.

Remote Sensor Installation

Installation of remote temperature and humidity sensors.

Condensate Pumps Installation

Installation and power requirements for optional condensate pumps.

Optional Disconnect Switch

Information on the optional disconnect switch feature.

Manual Override Switch Board

Using manual override switches for testing and startup.

Wiring Diagrams

Location and purpose of unit wiring diagrams.

Installation of Remote Outdoor Heat Exchanger

Charging the Refrigeration System

Package Air-Cooled Systems Charging

Charging procedures specific to package air-cooled units.

Charging and Installation Work Procedures

Basic procedures and special equipment for charging.

Triple Evacuation and Dehydration Procedure

Critical steps for system evacuation to remove moisture.

General Pre-Charging Guidelines

Essential checks and preparations before refrigerant charging.

Voltage Phase Check

Verifying voltage and phase for correct compressor operation.

Line Set Charge Calculations

Calculating required refrigerant weight for line sets.

Component Functional Test

Verifying the functionality of critical system components.

Charging Procedures

Detailed steps for charging refrigerant into the system.

Refrigerant Handling

Safe and regulatory compliant handling of refrigerants.

Air-Cooled Split System Charging

Charging procedures for split air-cooled systems.

Additional Oil Requirements

Guidelines for adding oil to the system during charging.

Flooded System Charging

Charging procedures for systems with low ambient receiver packages.

Refrigerant Receiver Function

Function and role of the refrigerant receiver in the system.

Refrigerant Receiver Applications

General applications for liquid refrigerant receivers.

Refrigerant Receiver Selection Guidelines

Guidelines for selecting appropriate refrigerant receivers.

Receiver Location Considerations

Considerations for locating receiver packages.

Safety Relief Devices

Information on fusible plug safety relief devices.

Receiver Installation

Instructions for installing receiver packages.

Important Refrigeration Components

Details on key components like TXV, cutout switches, and solenoid valves.

Glycol Systems

Glycol Concentration

Importance of correct glycol concentration for freeze protection.

Internal (Fluid) Volume

Data on unit fluid volumes for system calculations.

Fluid Cooler Internal Volume

Internal fluid volume for fluid cooler units.

Brazed-Plate Fin Condensers

Description of brazed-plate condenser construction and characteristics.

Water Treatment

Critical aspects of water treatment to prevent fouling and corrosion.

Fluid Cooler Operation

Operation and characteristics of fluid coolers.

Controls

Programmable Thermostat

Features of the standard thermostat controller.

Mini-dap4 Microprocessor Control Controller

Features and operation of the advanced Mini-dap4 controller.

Optional Expanded dap4 Microprocessor Controller

Features and operation of the Expanded dap4 controller.

Remote Heat Exchangers Controls

Control mechanisms for remote heat exchangers.

Regular Maintenance Items

Air Filter Maintenance

Inspection and replacement of air filters for optimal performance.

Belt Tension and Condition

Procedures for checking and maintaining belt tension.

Bearing Maintenance

Maintenance requirements for motor and blower bearings.

Fuse Replacement

Guidelines for changing fuses, including type and rating.

Electric Reheat Maintenance

Maintenance considerations for electric reheat elements.

Humidifier Maintenance

Maintenance and replacement of parts for optional humidifiers.

Refrigerant Filter Drier Replacement

When and how to replace the refrigerant filter drier.

EC Plenum (Plug) Fans Service

Maintenance and service for EC motor fan modules.

Frequently Asked Questions (FAQ)

Electrical FAQ Section

Answers to common electrical questions regarding the unit.

Mechanical FAQ Section

Answers to common mechanical and installation questions.

Contact Data Aire

Related product manuals