Data Aire DAMA-1.5 User Manual

Default Icon
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Other manuals for Data Aire DAMA-1.5

Question and Answer IconNeed help?

Do you have a question about the Data Aire DAMA-1.5 and is the answer not in the manual?

Data Aire DAMA-1.5 Specifications

General IconGeneral
BrandData Aire
ModelDAMA-1.5
CategoryAccessories
LanguageEnglish

Summary

Introduction and System Overview

Product Information and Model Identification

Details on unit specifications, types, and model number breakdown for identification.

Inspection, Paperwork, and Storage

Guidelines for unit inspection, required documentation, and proper storage conditions to maintain integrity.

Installation Procedures

Installation Planning and Room Requirements

Planning considerations, tool recommendations, and room suitability for unit installation.

Equipment Handling, Rigging, and Mounting

Safe procedures for moving, lifting, and securing the unit during installation.

Piping and Line Set Requirements

Guidance on refrigerant and fluid piping, line sizing, and connection types for various systems.

Electrical Installation and Commissioning

Procedures for field wiring, connections, and final system verification before operation.

Electrical Connections and Controls

Electrical Wiring Guidelines and Service Requirements

Standards for field wiring, conduit, voltage, and service connections.

Voltage Tolerance and Control Wiring

Acceptable voltage ranges and methods for connecting control and auxiliary wiring.

Controller Features and Operation

Information on Mini-dap4 controller, remote sensors, and alarm contacts.

Charging, System Operation, and Components

Evacuation, Dehydration, and Refrigerant Charging

Critical steps for system evacuation, moisture removal, and refrigerant charging for optimal performance.

System Charging Checks and Guidelines

Procedures for checking compressor phase, heat exchangers, and general charging guidelines.

Water/Glycol Systems Charging and Components

Charging for water/glycol systems, TXV, and pressure switches.

Specialized Systems and Maintenance

Glycol Systems: Concentration, Treatment, and Fluid Coolers

Information on glycol concentration, water treatment, and fluid cooler operation.

Regular Maintenance Items and Procedures

Routine checks for filters, belts, bearings, and other system components.

Maintenance/Inspection Checklist

A comprehensive checklist for periodic inspection and maintenance of the unit.

Frequently Asked Questions and Contact

Electrical and Mechanical FAQs

Answers to common electrical and mechanical questions regarding unit operation and installation.

Contact Data Aire for Support

Contact details for Data Aire Inc. including address, phone, email, and website.