Firmware Upgrades
The VisionSC-DP2 cards allow rmware upgrades to be completed on site rather than returning the card
to Datapath. Whenever a rmware upgrade is performed, the SW2 on the DIP switch must be set ON. The
DIP Switch can be located on the back of the VisionSC-DP2 (See Fig. 5 ). To perform the upgrade, follow
the step-by-step instructions provided by the upgrade application. The VisionSC-DP2 is shipped with the
SW2 switch set at ON, therefore no action should be necessary.
In the unlikely event that something goes wrong during the upgrade process (e.g. System power outage) it
is possible to revert to the factory settings by powering down the system, temporarily setting SW2 to the
OFF position then powering up the system. Once the system has rebooted, set the SW2 back to the ON
position (while the system is still powered up) and restart the rmware upgrade process.
It should be noted that the latest driver installation program includes an automatic rmware update, if
required. Therefore, prior to installing the application and driver, ensure that SW2 is set to ON.
12
Fig. 5

Other manuals for Datapath VisionSC-DP2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datapath VisionSC-DP2 and is the answer not in the manual?

Datapath VisionSC-DP2 Specifications

General IconGeneral
BrandDatapath
ModelVisionSC-DP2
CategoryPCI Card
LanguageEnglish

Related product manuals