For installations 21kW and over
Installing into main ltration system
Installing into existing solar heating system
1) The frame must be xed by bolts (M10) to concrete foundation or brackets. The concrete foundation must
be solid and fastened; the bracket must be strong enough and antirust treated;
2) Please ensure 50cm of clearance around each side of the Davey heat pump or the efciency of the heat
pump will be reduced;
3) Although a bypass system is not necessary for your Davey heat pump to operate properly, we strongly
recommend the installation of a bypass system to regulate the ow rate and make the maintenance and
winterising of the Davey heat pump easier.;