10
Trouble Shooting continued...
c) UV LAMP OUT, ALARM ON
1. Lamp failed.
2. Poor connection to lamp (check/clean connector/lamp pins).
3. Ballast failed (unlikely).
d) LAMP ON, ALARM ON
1. Faulty circuit board.
e) LAMP OUT, ALARM OFF
1. Loose connection or faulty circuit board, possibly short in lamp circuit.
Part Numbers
a) Lamp (SF2500S has 2 lamps and 2 sleeves)
SF1000/SF2500 GPH840N2/S
b) Sleeve
SF1000/SF2500 QS880
c) O-rings
All models S24x3N70 (2 per sleeve)
d) Lamp Connector
All models S114/2
WARNING: When servicing or attending your Steriflo
®
, always
ensure power is switched off and lead unplugged. Electrical
connections should be serviced only by qualified persons. If the
electrical supply lead of this system is damaged, it must only be
replaced by qualified personnel.
Care should also be taken when servicing or disassembling the
unit and associated pipework to avoid possible injury from
pressurised water. Unplug power, relieve pressure by opening a
tap on the discharge side of the unit and allow any water in the
unit to cool before attempting to dismantle.