EasyManuals Logo

Davis Instruments Vantage Pro2 Plus User Manual

Default Icon
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
Alarm Mode
33
Time
The time alarm is a standard “alarm clock” alarm. It sounds for one minute
at the set time. Make sure you choose AM or PM, if you’re in 12-hour
mode.
UV Dose
The UV dose alarm sounds when the accumulated UV dose has exceeded
the dose you set. The UV dose alarm does not arm unless the initial UV
dose for the day has been reset. Once the UV dose alarm value is set, clear
the accumulated UV dose. See “Clearing Weather Variables” on page 29.
Setting Alarms
1. Press ALARM to enter the Alarm Mode to view or set the high alarm
thresholds. The screen displays the current high alarm thresholds. The
ALARM and HIGHS icons also appear.
2. Press 2ND then press ALARM to enter the Alarm Mode to view or set
the low alarm thresholds. Then press HI/LOW to display the low alarm
threshold settings. The ALARM and LOWS icons display.
3. Press the right and left arrows to select one of the variables displayed on
the screen or use the console keys to select any weather variable.
4. Press 2ND then press SET to change the selected variable’s alarm set-
ting.
The right-most digit in the alarm threshold will begin blinking.
5. Press the right and left arrows to select digits in the threshold value.
6. Press the up and down arrows to change the digits value up and down.
7. Press DONE to finish changing the alarm setting.
8. Repeat steps 3 through 7 to change additional alarm settings.
9. Press DONE to exit Alarm Mode.
Setting the Time Alarm
1. Press ALARM to enter alarm mode.
The ALARM and HIGHS icons appear.
2. Press 2ND, then press TIME, then press 2ND again, and then press
ALARM.
The time field begins blinking.
3. Press the left and right arrows to select hours, minutes, or AM/PM.
4. Press up and down arrows to change the digit’s value up and down.
5. Press DONE to exit Alarm Mode.
Clearing Alarm Settings
1. Press ALARM to enter alarm mode.
The ALARM and HIGHS icons appear.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 Plus and is the answer not in the manual?

Davis Instruments Vantage Pro2 Plus Specifications

General IconGeneral
BrandDavis Instruments
ModelVantage Pro2 Plus
CategoryWeather Station
LanguageEnglish

Related product manuals