2
DDA900C is particularly suited to borehole applications and is supplied with an
external control box which incorporates an isolator, run indicator light, thermal
overload protection and starting capacitor which can be connected directly to
mains power. The box is also provided with auxiliary terminals for control probes,
pressure switch or float switch.
MOTOR
Enclosed and rewindable liquid cooled, non-overloading induction motor
designed for continuous operations incorporating a thermal cut-out in the
windings to protect against overloading. Pumps can be connected directly to the
mains power supply through a 10A fuse or MCB.
Enclosure Class: X8 Insulation Class: B Voltage: 1x240V
Speed: 2900rpm
OPERATING CONDITIONS
Pumped Liquids: Thin, chemically non aggressive liquids without solids or
fibres
0
Max. Liquid temperature: 35 C
Max. Immersion Depth: DDA1000P- 6m;DDA1200C2 - 20m; DDA900C -
16m
Max. Particle Size: DDA1000P -1.5mm; DDA900C & DDA1200C2 - 1.0mm
PUMP DATA
Model
Power
HP
kW
Max.
Current
(A)
Outlet
(”)
Dimensions (mm)
Weight
(kg)
WH
DDA 900C
1.2
0.9
645
11
100
3.9
1
1.2
0.92
577
18
128
6.5
DDA 1200C2
1.31.0
440
9.4
150
4
DDA 1000P
DDA 900C DDA 1200C2 DDA 1000P
H
w
H
w
H
w