PARAMETERS
25mm² / 3AWG
-20~+55°C
-30~+80°C
10%~90% No Condensation
IP32
< 3000m
RS485, RJ45 Port
Cat5
FCC Part 15 Class B; CE; RoHS
-4mV/°C/2V
Rated Battery Current
System Voltage
Rated Load Current
Max. Battery Voltage
General
Max Terminal Size
Working Temperature
Storage Temperature
Humidity Range
Enclosure
Altitude
Communication
Network Cable Type
Certification
Temp Compensation
Max Solar Input Power
100A
50A
SKU
Self-Consumption
MONT
57.6V
150V
60A
30A
12V / 650W,
24V / 1300W,
36V / 1950W,
48V / 2600W
≤35mA @ 12V/24V/36V/48V
40A
20A
12V/24V/36V/48V Auto Recognition
12V / 520W,
24V / 1040W,
36V / 1560W,
48V / 2080W
DC-MPPT-MPK2-40A DC-MPPT-MPK2-60A DC-MPPT-MPK2-100A
Electrical
Max Solar Input Voltage
BATTERY CHARGING PARAMETERS
Equalization Voltage
Boost Voltage
Float Voltage
Low Voltage Disconnect
Low Voltage Reconnect
SKU
14.4V
14.6V
10.8V
12.6V
13.8V
Gel Sealed Flooded Li
/
/
/
/
/
12V / 1300W,
24V / 2600W,
36V / 3900W,
48V / 5200W
* Parameters are multiplied by 2 for 24V systems, by 3 for 36V systems and by 4 for 48V systems.