S P A Z I O
Operatinginstructionsandwarnings
17
PROCEDUREDESCRIPTION
PROCEDURE
Positioning of the door/gate
Unused parameter
Memorization of the motors’ stroke
Deletion of the radio receiver memory
Transmitters memorization
Search and deletion of a transmitter
Resetting of default parameters
PARAMETERDESCRIPTION SETTABLEVALUES
1
USER
2
PARAMETRES
Type of coding of the radio receiver
HCS fixed part only
HCS rolling code
HT12E dip switch
Channel selection and linking to “start” and “pedestrian” inputs
start pedest. start pedest.
CH1 CH2
CH3 CH4
CH1 CH3
CH4 CH1
CH1 CH4
CH4 CH2
CH2 CH1
CH4 CH3
CH2 CH3
CH1 CH2
3
CH2 CH4
CH2 CH2
3
CH3 CH1
CH3 CH2
3
CH3 CH2
CH4 CH2
3
Motors’ speed during normal stroke (calculated as % of max speed)
Motors’ speed during slow-down phase (calculated as % of max speed)
Slow-down duration (expressed as % of total stroke)
Unused parameter
Motor’s force while opening (if = 100 --> max force, sensitivity on obstacle excluded)
Motor’s force while closing (if = 100 --> max force, sensitivity on obstacle excluded)
Unused parameter
Unused parameter
Selection of type of external safety device: rib / barrier. If the rib” modality is selected, the SIC
input activation inverts the movement direction; during slow-down phase, while if the barrier
modality is selected the movement is stopped.
“safety rib” mode
“photoelectric barrier” mode
Time of automatic closing (expressed in sec). If = 0 the automatic closing is deactivated
Time of pre-flashing (expressed in sec)
Unused parameter
Unused parameter
Collectivity function: if it is activated it deactivates both start and pedestrian inputs for the
whole duration of automatic opening and closing
deactivated
activated
Ram blow function: if it is activated, it pushes the motors closed for one second before each
opening movement, so as to ease motor’s start
deactivated
activated
Operating program: reversal (start->open, start->close, start->open ...), step-by-step
(start->open, start->stop, start-close...)
reversal
step-by-step
Photocell function even while opening: if it is activated, the photocell stops the movement while
opening until the obstacle is removed. In any case it reverses the direction of movement while
closing
Photocell activated only in closing
Photocell activated also in opening
Clean contact operation:
- If = 0, open gate fixed warning light, the contact is always closed when the gate is moving
or opened, it opens again only when the closing movement is completed
- If =1, open gate intermittent light, the contact is slow while opening and fast while closing,
always closed when the gate is opened, it opens again when the closing movement is
completed
- If>1 courtesy light, the contact is closed during every movement, it opens again when the
motor stops according to a pre-settable delay (expressed in sec)
open gate fixed warning light
open gate intermittent warning
light
courtesy light with settable delay-
off
Short reversal at end of stroke: when the door/gate reaches the end of stroke, it reverses shortly
the movement so as to “release” the mechanical stress due to the door/gate pressure on the
end of stroke itself
deactivated
activated
Unused parameter
“ PED “ input functioning
-If=0, it ensures the door or gate closing in any position, “AP” input works normally.
-If=1 the “PED” input starts the closing while “AP” starts the opening.
-If=2 the “PED” input (permanent command) starts the closing, the AP” input (permanent
command) starts the opening. The gate stops at release.
-If>2 “PED” starts the pedestrian opening. The selected value indicates the duration of the
pedestrian stroke (expressed as a % of the total stroke). The “AP” input normally works.
Central lock
Separate lock
Man present command
Pedestrian
Ramps-up rate
-If=0 The motor starts immediately at the selected speed
-If=1 The motor speeds up progressively until it reaches the selected speed
fast ramp
slow ramp
Reaction at detection of an obstacle while opening
-If=0 the door reverses travel direction
-If different from 0 the door reverses travel direction only for the time set (expressed in sec)
Reaction at detection of an obstacle while closing
-If=0 the door reverses travel direction
-If different from 0 the door reverses travel direction only for the time set (expressed in sec)
Unused parameter
1
The default value, set by manufacturer at the factory, is written in bold and underlined.
2
Column reserved to the installer to fill in with the automation personalised parameters Table2Parametres
3
Inactive channel.