PAGE 4
SETTING TRANSBRAKE DELAY (continued)
SETUP MODE
TB LOCKOUT 03
SETUP MODE
TB PAUSE .100
SETUP MODE
SKIP DOWN -.015
SKIP DOWN or SKIP UP: This is the amount of time you want to add
(Skip UP) or subtract (Skip Down) from your delay time after you have
released the transbrake button. If you feel you “missed” the tree, every
time you push the skip button the box will add or subtract this amount
from your delay time. Use the scroll arrows to change this setting.
TB PAUSE: This is the amount of time the box pauses from when the
transbrake button is depressed until the transbrake sets. This prevents
transbrake application if the button is acci
dentally bumped or brushed
while driving down the return road or in the staging lanes.
TB LOCK OUT: This is the amount of time the box will lock out the trans-
brake so the driver cannot re-apply the transbrake during the pass. Use
the scroll arrows or cursor button to change the lock out in increments of
whole seconds.
SETUP MODE
CROSS COMP .015
CROSS COMP: Crossover compensation time is used to compensate
for late lights when crossing over. When you cross over and leave off
your opponent’s tree, you get an indirect view of his top bulb instead of a
direct view like on your side. This results in a reaction time that is
about .010 to .020 seconds slower. Crossover compensation automati-
cally subtracts this time from your delay setting whenever you cross-
over. Use the scroll arrows or cursor button to change this setting.
NOTE: Cross comp should be set for 0.000 when running in Cross-
over
mode on a Cross Talk bracket tree.
FACTORY SETTINGS AND PARAMETERS
SETTING
DELAY
DELAY 2
THEIR E.T.
YOUR E.T.
BOTTOM DELAY
CROSS COMP
SKIP UP / SKIP DOWN
TB PAUSE
TB LOCK OUT
RANGE
0.000 to 1.999 sec.
0.000 to 1.999 sec.
00.00 to 19.99 sec.
00.00 to 19.99 sec.
0.00 to .299 sec.
.000 to .099 sec.
+.050 to –.050 sec.
0.000 to 1.999 sec.
00 to 19 seconds
PRO
.010
.010
10.90
9.90
.010
.015
-.010
.010
01
FULL
1.000
.500
10.00
9.00
.100
.015
-.010
.010
03
FACTORY
SETTINGS
PRO-FULL SETTING PARAMETERS:
PRO MODE = P/F LIGHT ON
FULL MODE = P/F LIGHT OFF