Code Text display Description Adjustment range 10 15 25 25/28
MI
35
CP240 ZoneRoomUnitInfl Adjustment of the influence
of the zone room unit
0 - 10 3 3 3 3 3
CP250 CalSondeAmbZon
e
Calibration of Zone Room
Unit
-5 °C - 5 °C 0 0 0 0 0
CP320 OperatingZoneMo
de
Operating mode of the zone 0 = Scheduling
1 = Manual
2 = Antifrost
3 = Temporary
1 1 1 1 1
CP340 TypeReducedNigh
tMode
Type of reduced night mode,
stop or maintain heating of
circuit
0 = Stop heat demand
1 = Continue heat
demand
0 0 0 0 0
CP470 Zone screed
drying
Setting of the screed drying
program of the zone
0 Days – 30 Days 0 0 0 0 0
CP480 ScreedStartTemp Setting of the start
temperature of the screed
drying program of the zone
20 °C – 50 °C 20 20 20 20 20
CP490 ScreedStopTemp Setting of the stop
temperature of the screed
drying program of the zone
20 °C – 50 °C 20 20 20 20 20
CP510 Temporary Room
Setp
Temporary room setpoint
per zone
5 °C – 30 °C 20 20 20 20 20
CP550 Zone, fire place Fire Place mode is active 0 = Off
1 = On
0 0 0 0 0
CP570 ZoneTimeProg
Select
Time Program of the zone
selected by the user
0 = Schedule 1
1 = Schedule 2
2 = Schedule 3
0 0 0 0 0
CP660 Icon display zone Choice icon to display this
zone
0 = None
1 = All
2 = Bedroom
3 = Livingroom
4 = Study
5 = Outdoor
6 = Kitchen
7 = Basement
3 3 3 3 3
CP730 Zone Heat up
speed
Selection of heat up speed
of the zone
0 = Extra Slow
1 = Slowest
2 = Slower
3 = Normal
4 = Faster
5 = Fastest
3 3 3 3 3
CP740 Zone cool down
speed
Selection of cool down
speed of the zone
0 = Slowest
1 = Slower
2 = Normal
3 = Faster
4 = Fastest
2 2 2 2 2
CP750 MaxZone Preheat
time
Maximum zone preheat time 0 Min – 240 Min 90 90 90 90 90
CP770 Zone Buffered The zone is after a Buffer
tank
0 = No
1 = Yes
0 0 0 0 0
CP780 Control strategy Selection of the control
strategy for the zone
0 = Automatic
1 = Room Temp based
2 = Outdoor Temp
based
3 = Outdoor&Room
based
0 0 0 0 0
9 Settings
86 AMC 7686707 - v.01 - 06092018