4.3 Changing the settings
4.3.1. Setting the set point temperatures
To set the various heating, DHW and swimming pool temperatures,
proceed as follows:
1. Press the
C
key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.
To go back to the previous display, press the key
j
.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
To cancel, press key
h
.
Menu C
Parameter Adjustment range Description Factory setting
DAY TEMP. A
5 to 30 °C Desired room temperature in comfort periods on circuit A 20 °C
NIGHT TEMP. A
5 to 30 °C Desired room temperature in reduced periods on circuit A 16 °C
ROOMTEM.COOL A
(1)
(2)
22 to 30 °C Desired room temperature set point in cooling mode 25 °C
DAY TEMP. B
(2)
5 to 30 °C Desired room temperature in comfort periods on circuit B 20 °C
NIGHT TEMP. B
(2)
5 to 30 °C Desired room temperature in reduced periods on circuit B 16 °C
ROOMTEM.COOL B
(2)
(1)
22 to 30 °C Desired room temperature set point in cooling mode 25 °C
DAY TEMP. C
(2)
5 to 30 °C Desired room temperature in comfort periods on circuit C 20 °C
NIGHT TEMP. C
(2)
5 to 30 °C Desired room temperature in reduced periods on circuit C 16 °C
ROOMTEM.COOL C
(2)
(1)
22 to 30 °C Desired room temperature set point in cooling mode 25 °C
WATER TEMP.
(2)
10 to 65 °C Desired domestic hot water temperature in the DHW circuit 55 °C
TEMP.TANK AUX
(2)
10 to 80 °C
Desired domestic hot water temperature in the auxiliary
circuit
55 °C
DHW A TEMP.
(2)
10 to 80 °C Desired domestic hot water temperature in circuit A 55 °C
TEMP.SOL.TANK
(2)
10 to 80 °C Temperature of the hot water produced by solar power (TS) 55 °C
SWIMMING P.T.B
(2)
5 to 39 °C Desired temperature for swimming pool B 20 °C
SWIMMING P.T.C
(2)
5 to 39 °C Desired temperature for swimming pool C 20 °C
(1) The parameter is only displayed if the corresponding circuit can handle cooling.
(2) The parameter is only displayed for the options, circuits or sensors actually connected.
MODE
C002266-A
AWHP MIT-IN iSystem 4. Operating the appliance
06/09/2012 - 300027618-001-01
16

Other manuals for DeDietrich AWHP MIT-IN iSystem

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DeDietrich AWHP MIT-IN iSystem and is the answer not in the manual?

DeDietrich AWHP MIT-IN iSystem Specifications

General IconGeneral
BrandDeDietrich
ModelAWHP MIT-IN iSystem
CategoryHeat Pump
LanguageEnglish

Related product manuals