PAGE 3 OF 8
Safety compliance with local requirements
This appliance is supplied ex-factory with jets and air settings for use with
LPG gas only.
Temporary installation
A flexible hose connection from the gas appliance to the cylinder may be made . Ensure that
the pipe clamps are tightened correctly and are of good quality.
Flexible hose - Not supplied.
Any hose that is used to connect the stove to the gas system shall comply with SANS
1156-2 or BS 3212.
Gas cylinder - Not supplied.
For best results we recommend that gas cylinders with a minimum capacity of 19kg be
used.
Regulator - Not supplied.
A 2,8 kPa LPG gas regulator which complies with SANS 1237 must be used.
This appliance uses LPG ( Liquid Petroleum Gas also known as bottle gas).
The bottle must be fitted with an approved regulator.
The manufacturer and the seller do not accept responsibility for any damage due to
incorrect installation or gas connection.
Soak the end of the plastic hose in hot water to soften it and then push the hose end fully
over the hose nozzle. (See sketch 1 below)
Secure the hose by tightening the hose clamp. ( See sketch 2 below)
In a similar fashion, secure the other end of the hose to the regulator on the gas bottle.
1
O Seal
and nozzle
Clamp
and hose
REGULATOR