Delem
V0802, 4.12
Parameter: 7
Max X1X2 difference
Range : 0 - 9999
Default : 0
Units : mm
Function
To program the maximum allowed difference between the two X-axes.
Description
With this parameter a maximum allowed difference in values between the X1- and X2-axis can
be programmed.