Parameter 25: Correction (Z)
Range : -9.999 - +9.999
Default : 0.000
Units : mm / 100mm
Remark : In case of R1-axis, R2-axis
Function
To compensate for mechanical deviations during Z1Z2-axis movements.
Description
When the Z1Z2-axis moves to another position it is possible that the R1(R2)-axis position
changes. You can use this parameter to program a position correction.
See figure 4.2m how to program the parameter. Notice the sign of the parameter value!
Correction (Z) = measured value - programmed value
Example
= 80 mm - 81 mm = -1mm / 25 mm
= -4 mm / 100 mm
Figure 5.2.f