Delem
V1101, 5.25
Parameter 26: Correction (R)
Range : -9.999 - +9.999
Default : 0.000
Units : mm / 100mm
Remark : In case of X2-axis
Function
To compensate for mechanical deviations during R-axis movements.
Description
When the R-axis moves to another position it is possible that the X2-axis position changes. You
can use this parameter to program a position correction.
See figure 4.2n how to program the parameter. Notice the sign of the parameter value!
Correction (R) = measured value - programmed value
Example
= 100.8 mm - 100 mm = 0.8 mm / 20 mm
= 4 mm / 100 mm
Figure 5.2.g