Delem
V0303, 5.29
Parameter 131: Safety speed
Range : 0 - 100
Default : 1
Units : %
Function
To program a low, safe speed for the backgauge when it is within a programmed distance from
the die.
Description
Low speed setting for the backgauge, valid when it is within the safety distance from the die. See
parameter 130, Safety distance, for more information. This speed is programmed in a percentage
of the maximum speed.