Delem
V1101, 2.6
Make a backup of the current control software with ‘create backup’. It is very important to create
a backup, because the new software overwrites the current software. Without a backup you
might loose valuable information.
Note
When loading a new software version the new software is checked first. If the size of the files on
the floppy is not correct, the message appears: ** new software too large for memory **.
Note
Starting the control after the update procedure results in the following message:
** parameters in manual mode have been set to initial values **.
This means that the programmed data in the manual mode are lost. This also includes that the
previous selected program in the auto mode is not active anymore.
Emergency procedure software installation
In case the above described procedure for updating the control software did not succeed, you can
always install the new software following the next procedure. The main difference is that there is
no check and there is no backup created.
Step 1: Put the floppy disk in the diskdrive of your control.
Step 2: Switch the power OFF.
Step 3: Switch the power ON.
Step 4: Press ‘7' immediately after switching the control on. Software is automatically loaded.
The files on the application floppydisk
APPL.CMD Installation batch file. Contains information for the control how to
install the files that are included in this file. You can easily edit this file
with a DOS-editor or ASCII-editor.
D*.A00 Application program file: Contains the application for the control.
KO-NNN.BIN KO-table file (the number NNN differs for each machine supplier).
Contains the specification for the unique parameters of the machine. For
example: type of hydraulic valve.
PRESS.DEF Text file with text definitions of the numbers in the sequencer file.
Contains definition macro’s for use in sequencer source.
SEQ_INP.TXT Sequencer file: Contains information on the mapping of the internal I/O
of the control to the outside I/O (PLC-functionality).
TXT_NNN.BIN Language text file (for each language a separate file): Contains the text
strings of the menus of the control per language. For example: NNN =
GB than the language file is english, NNN = I than the language file is
italian, etc.