Make sure to place and seal the silicone valve correctly – refer to the vacuum valve assembly/disassembly instructions ( PICTURES, pic. 3). Incorrect assembly can lead to poor or no
vacuuming performance.
•
Use small cup and 2 wing blade assembly only for dry ingredients.
•
If the food sticks to the wall of the blender jar, switch o the device and unplug it. Then use soft spatula (not supplied with the product) to remove the food from the wall.
•
If bubbles/foam expands beyond the MAX level indication, stop the vacuum operation immediately.
•
Never vacuum or blend carbonated beverages. Build up pressure from released gasses can cause container to burst, resulting in possible injury.
4.1 MODES (see: PICTURES, pic. 2)
Modes (see: PICTURES, pic. 2)
HB – HEATING & BLENDING
B - BLENDING
0 – MODE 0
VB – VACUUM BLENDING
V - VACUUM
P - PULSE
(ON/OFF) – START/STOP
First check and get familiar with control panel, pulse button, mode knob and its modes.
4.1.1 MODE 0 (see: PICTURES, pic. 4)
Before use and when operation is nished, always turn the knob to “0” position.
4.1.2 MODE V: VACUUMING (see Pictures, pic. 9)
USAGE WITH 700 ML CUP AND 6 WING BLADE ASSEMBLY
•
Assemble the vacuum valve set (holder + valve + valve protector) to the cup by rotating it clockwise until cup’s indicator points on the doted locked eld marked on the valve holder.
(see Pictures, pic. 5).
•
Fill in the ingredients up to the MAX level marked on the cup (see Pictures, pic. 6).
NOTE: The content should never exceed the MAX level.
•
Assemble the blade assembly to the cup by rotating it clockwise until cup’s indicator points on the doted locked eld marked on the blade assembly (see Pictures, pic. 7a)).
•
Place the cup onto the main unit and rotate it clockwise until you hear »click« sound (see Pictures, pic. 7b)).
•
Insert the vacuuming device into the main body (remove cover before that if needed) (see Pictures, pic. 8a)), ip it to 90°, attach the vacuuming nozzle onto the valve and press the
head down slightly (see Pictures, pic. 8b)).
•
Rotate the knob to mode V - you will hear the beep sound when in position and the mode light will start to ash. Press the knob to start the V cycle, you will hear the beep sound and
the mode light will turn on (see Pictures, pic. 9). After the cycle is completed, the device will stop and switch to stand by mode automatically. The mode light will start to ash again.
•
Device vacuums until maximum vacuum is reached.
•
Lift the vacuuming head and disassemble the cup from the main device.
•
Store the vacuumed cup and content or release the vacuum by gently pulling the silicone valve ap – lifting it just enough to hear air being sucked in. (see Pictures, pic. 10 a))
•
NOTE: You do not need to remove valve to release the vacuum.
•
Always release the vacuum rst before opening the 700 ml cup
•
It is advised to reposition the valve right away after releasing air (see Pictures, pic. 10 b) and c)).
•
it is important that the vacuum valve holder is washed well and dried thoroughly after every use to remove possible food residues. Only this way the vacuuming performance is optimal.
USAGE WITH VACUUM STORAGE CONTAINERS, BAGS OR VACUUM BOTTLE STOPPER (see Pictures, pic. 11)
•
Assemble the vacuum tube on the vacuuming device.
•
Select the vacuuming head with smaller or larger diameter (according to the selected vacuuming valve). Disassemble if you need one with smaller diameter.
•
VACUUM STORAGE CONTAINERS: Put in the ingredients and make sure that it is locked well. Place the vacuuming head over the valve and hold at against it rmly. Use the mode V
according to the instructions above. To release the vacuum, lift the valve and open the container.
•
VACUUM STORAGE BAGS: Put in the ingredients and make sure that it is sealed well. Place the vacuuming head over the valve and hold at it rmly. Use the mode V according to the
instructions above. To release the vacuum, unzip the bag.
•
BOTTLE STOPPER: Insert the bottle stopper into the bottle neck. Place the vacuuming head over the valve and hold it at against rmly. Use the mode V according to the instructions
above.
The vacuuming device can be used independently (without the main unit) as well. Insert 4x 1,5 V AA batteries in the battery compartment according to instructions in battery compartment. (see
Pictures, pic. 12 a,b) Use it with vacuuming tube or press the vacuuming device nozzle onto the vacuum valve directly (if ts to the size) and vacuum by pressing the vacuuming button until it
stops automatically indicating that maximum vacuum has been reached.
4.1.3 MODE VB: VACUUMING AND BLENDING (see Pictures, pic. 13)
USAGE WITH 700ML CUP AND 6 WING BLADE ASSEMBLY
•
Assemble the vacuum valve set (holder + valve + valve protector) to the cup by rotating it clockwise until cup’s indicator points on the doted locked eld marked on the valve holder
(see Pictures, pic. 5).
•
Fill in the ingredients up to the MAX level marked on the cup (see Pictures, pic. 6).
NOTE: The content should never exceed the MAX level.
•
Assemble the blade assembly to the cup by rotating it clockwise until cup’s indicator points on the doted locked eld marked on the blade assembly (see Pictures, pic. 7a)).
•
Place the cup onto the main unit and rotate it clockwise until you hear »click« sound (see Pictures, pic. 7b)).
•
Insert the vacuuming device into the main body (see Pictures, pic. 8a)), ip it to 90°, attach the vacuuming head onto the valve and press it down slightly (see Pictures, pic. 8b)).
•
Rotate the knob to mode VB - you will hear the beep sound when in position and the mode light will start to ash. Press the knob to start the VB cycle, you will hear the beep sound and
the mode light will turn on (see Pictures, pic. 13)). After the cycle is completed, the device will stop and switch to stand by mode automatically. The mode light will start to ash again.
•
VB cycle: vacuuming + 3 x pulsing + 30 s blending
•
Lift the vacuuming head and disassemble the cup from the main device.
•
Store the vacuumed cup and content or release the vacuum by gently pulling the silicone valve ap – lifting it just enough to hear air being sucked in. (see Pictures, pic. 10 a)).
NOTE: You do not need to remove valve to release the vacuum.
•
Always release the vacuum rst before opening the 700 ml cup.
•
It is advised to reposition the valve right away after releasing air (see Pictures, pic. 10 b) and c)).
•
it is important that the vacuum valve holder is washed well and dried thoroughly after every use to remove possible food residues. Only this way the vacuuming performance is optimal.
4.1.4 MODE B: BLENDING (see Pictures, pic. 14)
USE WITH 700ML CUP/6 WING BLADE ASSEMBLY, 200ML CUP/2 WING BLADE ASSEMBLY OR FOOD PROCESSOR ATTACHMENT OR HEATING JUG
700ML CUP
•
Assemble the vacuum valve set (holder + valve + valve protector) to the cup by rotating it clockwise until cup’s indicator points on the doted locked eld marked on the valve holder
(see Pictures, pic. 5).
•
Fill in the ingredients up to the MAX level marked on the cup (see Pictures, pic. 6).
NOTE: The content should never exceed the MAX level.