Public switch: Arista 7050SX-64
The 7050SX-64 switch is a 52-port switch. The switch is equipped with 52 SFP+
ports, dual hot-swap power supplies, and redundant, field-replaceable fan modules.
Figure 12 Arista 7050SX-64 ports
Table 23 7050SX-64 switch port connections used on the top 10 GbE switch (
hare
)
Figure label Ports Connection description
1 1–8 The 10 GbE uplink data ports. These ports provide the
connection to the customer's 10 GbE infrastructure. SR Optic.
See note.
2 9–32 The 10 GbE node data ports, only ports 9–16 are used in the
U- and D-Series. These ports are connected to the left 10 GbE
(P02) interface on each node. SR Optic.
3 33–44 Unused.
4 45–48 The 10 GbE LAG ports. These ports are connected to the LAG
ports on the other 10 GbE switch (
rabbit
). SR Optic.
5 49–52 Unused.
6 <...> The 1 GbE management port. This port is connected to port
50 of the management switch (
turtle
). RJ-45.
7 Serial console The console port is used to manage the switch through a
serial connection. The Ethernet management port is
connected to the 1 GbE management switch.
Table 24 7050SX-64 switch port connections used on the bottom 10 GbE switch (
rabbit
)
Figure label Ports Connection description
1 1–8 The 10 GbE uplink data ports. These ports provide the
connection to the customer's 10 GbE infrastructure. SR Optic.
See note.
2 9–32 The 10 GbE node data ports, only ports 9–16 are used in the
U- and D-Series. These ports are connected to the right 10
GbE (P01) interface on each node. SR Optic.
3 33–44 Unused.
4 45–48 The 10 GbE LAG ports. These ports are connected to the LAG
ports on the other 10 GbE switch (
hare
). SR Optic.
5 49–52 Unused.
Switches