Function/Feature Supported
NOTE: Performed on virtual disk creation by default.
Background initialization No
RAID0 No
RAID1 Yes
Single non-RAID Yes
Dual non-RAID Yes
Degraded RAID1 and non-RAID No
Foreign import Yes
Consistency check No
Patrol read No
Load balance N/A
Rebuild Yes
NOTE: Manually triggered in Human Interface Infrastructure(HII) or via Marvell
Command Line Interface (CLI).
Auto-rebuild Yes
NOTE: Auto Rebuild will occur at power up only if there is a surviving native
virtual disk and another physical disk is present at power up.
Hot spare No
Change rebuild priority/rate No
Virtual disk write back/ read ahead cache No
NOTE: No controller cache.
Battery support N/A
NOTE: No battery.
Non-RAID disk cache policy Yes
NOTE: OS controlled/Device defaults.
SMART Info Yes
NOTE: Can be pulled by Marvell CLI.
Physical disk hot swap No
Virtual disk expansion No
Virtual disk slicing No
Virtual disk migration Yes
NOTE: On new controller, virtual disk must be Imported from HII before
presented to OS.
Split mirror No
NOTE: System required to shutdown and migrate one physical disk to another
system and continue rebuild.
Non-RAID migration Yes