LEDs
LED colors are used consistently throughout the enclosure and its components for indicating status:
Green – Good or positive indication
Blinking green/amber – Non-critical condition
Amber – Critical fault
Blue – Controller module or IOM identification
Topics:
ME484 JBOD storage enclosure LEDs
12 Gb/s expansion module LEDs
DDIC LEDs
Drawer LEDs
Fan cooling module LEDs
Ops panel
PSU LEDs
ME484 JBOD storage enclosure LEDs
When the ME484 JBOD storage enclosure is powered on, all LEDs turn on for a short period to ensure that they are working.
NOTE:
This behavior does not indicate a fault unless LEDs remain lit after several seconds.
12 Gb/s expansion module LEDs
ME484 JBOD storage enclosures are configured with dual expansion modules.
Figure 7. ME484 JBOD storage enclosure expansion module LEDs
Table 1.
ME484 JBOD storage enclosure LED descriptions
LED Description Definition
1 Identify Blue – Expansion module is being identified.
2 Fault
Off – The expansion module is operating normally.
Amber – A fault has been detected or a service action is required.
3 OK
Green – The expansion module is operating normally.
Blinking green – System is booting.
Off – The expansion module is powered off.