Figure 6. CutoverSynchronized
Following a cutover, the two paths to the source array are inactive (FAs 7e:00 and 8e:00) and the four paths to the target are active. In
PowerPath, the terms used are "dead" and "alive".
Note: The PowerPath mode is "active" for all paths. This is a PowerPath term and is unrelated to the active and inactive
path states in NDM terminology. PowerPath will show the state of the path and whether it is alive or dead in the
“state” field.
C:>powermt display dev=all
Pseudo name=harddisk1
Symmetrix ID=000195703184
Logical device ID=0158
Device WWN=60000970000195703184533030313538
state=alive; policy=SymmOpt; queued-IOs=0
==============================================================================
--------------- Host --------------- - Stor - -- I/O Path -- -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
2 port2\path0\tgt6\lun1 c2t6d1 FA 1d:61 active alive 0 0
2 port2\path0\tgt5\lun1 c2t5d1 FA 1d:60 active alive 0 0
2 port2\path0\tgt4\lun0 c2t4d0 FA 7e:00 active dead 0 0
1 port1\path0\tgt6\lun1 c1t6d1 FA 2d:61 active alive 0 0
1 port1\path0\tgt5\lun1 c1t5d1 FA 2d:60 active alive 0 0
1 port1\path0\tgt4\lun0 c1t4d0 FA 8e:00 active dead 0 0
Pseudo name=harddisk2
Symmetrix ID=000195703184

Table of Contents