NOTE: If there is a persistence policy in effect and the virtual addresses, initiator, or storage targets are set on a CNA-
device partition, do not reset or clear the values configured for virtual addresses, initiator, and storage targets before
changing the VirtualizationMode or the personality of the partition. The action is performed automatically when you
disable the persistence policy. You can also use a configuration job to explicitly set the virtual address attributes to 0s
and the initiator and storage targets values as defined in iSCSI initiator and storage target default values.
Related links
Enabling or disabling I/O Identity Optimization
Configuring persistence policy settings using iDRAC web interface
To configure the persistence policy:
1. In the iDRAC Web interface, go to OverviewHardwareNetwork Devices.
The Network Devices page is displayed.
2. Click I/O Identity Optimization tab.
3. In the Persistence Policy section, select one or more of the following for each persistence policy:
A/C Power Loss - The virtual address or target settings persist when AC power loss conditions occur.
Cold Boot - The virtual address or target settings persist when cold reset conditions occur.
Warm Boot - The virtual address or target settings persist when warm reset condition occurs.
4. Click Apply.
The persistence policies are configured.
Configuring persistence policy settings using RACADM
To set persistence policy, use the following racadm object with the set sub command:
For virtual addresses, use iDRAC.IOIDOpt.VirtualAddressPersistencePolicyAuxPwrd and
iDRAC.IOIDOpt.VirtualAddressPersistencePolicyNonAuxPwrd objects
For initiator, use iDRAC.IOIDOPT.InitiatorPersistencePolicy object
For storage targets, use iDRAC.IOIDOpt.StorageTargetPersistencePolicy object
For more information, see the iDRAC RACADM Command Line Interface Reference Guide available at dell.com/esmmanuals.
iSCSI initiator and storage target default values
The following tables provide the list of default values for iSCSI initiator and storage targets when the persistence policies are
cleared.
Table 32. iSCSI initiator —default values
iSCSI Initiator Default Values in IPv4 mode Default Values in IPv6 mode
IscsiInitiatorIpAddr 0.0.0.0 ::
IscsiInitiatorIpv4Addr 0.0.0.0 0.0.0.0
IscsiInitiatorIpv6Addr :: ::
IscsiInitiatorSubnet 0.0.0.0 0.0.0.0
IscsiInitiatorSubnetPrefix 0 0
IscsiInitiatorGateway 0.0.0.0 ::
IscsiInitiatorIpv4Gateway 0.0.0.0 0.0.0.0
IscsiInitiatorIpv6Gateway :: ::
180