Stacking Dell PowerConnect Switches: 8132, 8132F, 8164, 8164F 
55 
 
Appendix A – Commands used in this document 
 
All CLI commands used in this document, along with a brief description, are listed below in order of 
appearance.  Some commands are used multiple times in the document. 
 
Shows running configuration 
Shows all stack members and roles 
hardware profile portmode 4x10g (from config-if) 
Changes a QSFP+ port to 4x10G 
boot auto-copy-sw (from config#) 
Allows for automatic firmware updates 
Shows available ports for stacking 
show switch stack-ports | include Stack 
Shows only ports in stack mode 
stack-port fortygigabitether 1/1/1 stack (from config-
stack#) 
Turns on stacking on a port 
copy running-config startup-config 
Backs up the running configuration 
Shows firmware and CPU versions on units 
copy tftp://10.10.1.10/PC8100v5.0.0.3.stk backup 
Example of firmware download using tftp 
Activates the backup image to be active 
Blinks the locate LED on rear of switch 
no member 5 (from config-stack#) 
Removes a unit from the stack config 
switch 4 renumber 3 (from config#) 
Renumbers a unit in the stack 
standby 3 (from config-stack#) 
Changes the standby to another unit 
initiate failover (from config-stack#) 
Causes Master to failover to the standby 
 
 
Appendix B - Network switch versions 
Version information for the network switches used in creating this document are as follows:  
5.0.0.3, 5.0.0.4,  5.1.0.0 
 
 
 
 
About Dell 
Dell is a leading technology provider to commercial and public enterprises around the world.