support.dell.com Dell PowerEdge 2x50 and PowerApp 200 Systems Rack Installation Guide13
,QVWDOOLQJWKH&DEOH0DQDJHPHQW$UP
To install the cable-management arm on the back of the system, perform the follow-
ing steps:
1. Facing the back of the rack cabinet, locate the threaded hole on the back of the
slide assembly and secure the end of the cable-management arm (the end having
a bracket and thumbscrew) to the right side vertical rail (see Figure 11).
The bracket snaps into the square mounting holes on the vertical rail and is
secured with the captive thumbscrew.
)LJXUH,QVWDOOLQJWKH&DEOH0DQDJHPHQW$UP
2. Align the free end of the cable-management arm (the end with the half-hinge) to
the hinge-half mate on the back right side (as viewed from the back) of the
system.
3. Squeeze the quick-disconnect knobs on the free end of the cable-management
arm and align the two hinge halves to attach the arm to the bracket on the back of
the system chassis (see Figure 11).
quick-disconnect knobs
captive
thumbscrew