EasyManuals Logo

Dell PowerEdge 2950 Information Update

Dell PowerEdge 2950
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Information Update 15
LCD Status Messages Update
Table 1-2 lists updates to the LCD status messages that can occur on
the PowerEdge 2950 III system and the probable cause for each message.
The LCD messages refer to events recorded in the system event log (SEL).
For information on the SEL and configuring system management settings,
see your systems management software documentation.
Table 1-2. LCD Status Messages
Code Text Causes Corrective Actions
N/A SYSTEM NAME A 62-character string that
can be defined by the user
in the System Setup
program.
The SYSTEM NAME
displays under the
following conditions:
The system
is powered on.
The power is off
and active errors
are displayed.
This message is for
information only.
You can change
the system ID and
name in the System
Setup program.
See “Using the System
Setup Program” in the
Hardware Owner’s
Manual.
E1000 FAILSAFE,
Call Support
Check the system event
log for critical failure
events.
See “Getting Help” in
the Hardware Owner’s
Manual.
E1118 CPU Temp
Interface
The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan
speed to maximum
as a precautionary
measure.
Turn off power to the
system and restart the
system. If the problem
persists, see “Getting
Help” in the Hardware
Owner’s Manual.

Table of Contents

Other manuals for Dell PowerEdge 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 2950 and is the answer not in the manual?

Dell PowerEdge 2950 Specifications

General IconGeneral
Tcase67 °C
Bus typeFSB
SteppingE0
FSB ParityYes
Processor codeSLBBP
Processor cache12 MB
Processor cores4
Processor modelE5405
System bus rate- GT/s
Processor seriesIntel Xeon 5400 Series
Processor socketLGA 771 (Socket J)
Processor codenameHarpertown
Motherboard chipsetIntel® 5000X
Processing Die size214 mm²
Processor frequency2 GHz
Processor cache typeL2
Processor lithography45 nm
Processor manufacturerIntel
Processor package size37.5 x 37.5 mm
Processor front side bus1333 MHz
Processor operating modes64-bit
ECC supported by processorNo
Thermal Design Power (TDP)80 W
Number of processors installed1
CPU multiplier (bus/core ratio)6
Number of Processing Die Transistors820 M
HDD size3.5 \
HDD capacity160 GB
HDD interfaceSerial ATA
Total storage capacity3320 GB
Maximum storage capacity6 TB
Graphics cardES1000
Memory slots8x DIMM
Internal memory4 GB
Memory clock speed667 MHz
Internal memory typeDDR2-SDRAM
Maximum internal memory64 GB
Memory layout (slots x size)2 x 2 GB
Maximum graphics card memory16 MB
Networking featuresBroadcom NetXtreme IITM 5708 Gigabit5 Ethernet NIC
Supported network protocolsTOE (TCP/IP)
Other network protocols supportediSCSI Boot
PS/2 ports quantity0
USB 2.0 ports quantity5
Bundled softwareSymantec Backup ExecTM 12.5 Symantec Backup ExecTM System Recovery 8.5 CommVault 7.0 Vizioncore
Compatible operating systemsMicrosoft Windows Server 2008, Microsoft Windows Server 2003 Red Hat Linux Enterprise SUSE Linux Enterprise Server 10 x86-64 VMware ESX 3.5
Chassis typeRack (2U)
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)-40 - 65 %
Operating relative humidity (H-H)20 - 80 %
CertificationFCC (U.S. only) Class A ICES (Canada) Class B CE Mark (EN 55022 Class B, EN55024, EN61000-3-2, EN61000-3-3) VCCI (Japan) Class B BSMI (Taiwan) Class A C-Tick (Australia/New Zealand) Class B SABS (South Africa) Class B CCC (China) Class B MIC (Korea) Class B UL 60950 CAN/CSA C22.2 No. 60950 EN 60950 IEC 60950
Processor ARK ID33079
Weight and Dimensions IconWeight and Dimensions
Depth744 mm
Width444.3 mm
Height86.4 mm
Weight23000 g