E2021 Incorrect
memory
configuration.
Review User
Guide.
Incorrect memory
configuration.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 177.
E2022 General
failure
during POST.
Check screen
message.
General failure after video. Check screen for specific
error messages.
E2023 BIOS Unable to
mirror memory.
Check DIMMs.
The system BIOS could
not enable memory
mirroring because of a
faulty memory module or
an invalid memory
configuration.
See "Troubleshooting
System Memory" on
page 177.
E2110 Multibit Error
on DIMM ##.
Reseat DIMM.
The memory module in
slot “##” has had a
multi-bit error (MBE).
See "Troubleshooting
System Memory" on
page 177.
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has
disabled memory
single-bit error (SBE)
logging and does not log
anymore SBEs until the
system is rebooted. "##"
represents the memory
module implicated by
the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 177.
E2112 Memory spared
on DIMM ##.
Power cycle
AC.
The system BIOS has
spared the memory
because it has determined
the memory had too many
errors. "##" represents the
memory module
implicated by the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 177.
Code Text Causes Corrective Actions