Figure 85. Configuration 9: 8 x 2.5-inch NVMe RAID with fPERC (H755N)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 88. 8 x 2.5-inch NVMe RAID with fPERC (H755N)
Order From To
1 SL3_CPU1_PA2 (signal connector on system
board)
CTRL_DST_PA1 (fPERC input
connector)
2 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power
connector)
3 CTRL_SRC_PB1 (fPERC controller connector) BP_DST_PA2 (backplane signal
connector) and BP_DST_PB2
(backplane signal connector)
4 CTRL_SRC_PA1 (fPERC controller connector) BP_DST_PA1 (backplane signal
connector) and BP_DST_PB1 (backplane
signal connector)
NOTE: An 8 x 2.5-inch NVMe backplane with fPERC H755 should be assembled outside and inserted into the system, along
with all necessary cables.