Loading...
NOTE: An 8 x 2.5-inch NVMe backplanes with fPERC H965i should be assembled outside and inserted into the system,
along with all necessary cables.
Figure 91. Configuration 15: 16 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 94. 16 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
Order From To
1 SL3_CPU1_PA2 (signal connector on system
board)
CTRL_SRC_PA1 (fPERC controller
connector)
2 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power
connector)
3 CTRL_SRC_SB1 (fPERC controller connector) BP_DST_SA1 (backplane signal
connector)
4 SIG_PWR_2 (system board power connector) BP_PWR_1 (backplane power
connector)
138 Installing and removing system components