NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 96. 16 x 2.5-inch SAS/SATA + 8 x 2.5-inch NVMe with fPERC (HBA355i, H355, H755)
Order From To
1 SL1_CPU2_PB1 (signal connector on system
board) and SL2_CPU2_PA1 (signal connector on
system board)
BP_DST_PB1 (backplane signal connector)
and BP_DST_PA1 (backplane signal
connector)
2 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
3 SL3_CPU1_PA2 (signal connector on system
board)
CTRL_DST_PA1 (fPERC input connector)
4 CTRL_SRC_SB1 (fPERC controller connector) BP_DST_SA1 (backplane signal connector)
5 SIG_PWR_2 (system board power connector) BP_PWR_1 (backplane power connector)
6 SL4_CPU1_PB2 (signal connector on system
board)
CTRL_DST_PA2 (fPERC input connector)
7 SL7_CPU1_PB4 (signal connector on system
board)
CTRL_DST_PB2 (fPERC input connector)
8 SIG_PWR_0 (system board power connector) BP_PWR_1 (backplane power connector)
Figure 94. Configuration 18: 16 x 2.5-inch SAS/SATA + 8 x 2.5-inch NVMe with fPERC (H965i)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 97. 16 x 2.5-inch SAS/SATA + 8 x 2.5-inch NVMe with fPERC (H965i)
Order From To
1 SL1_CPU2_PB1 (signal connector on system
board) and SL2_CPU2_PA1 (signal connector on
system board)
BP_DST_PB1 (backplane signal connector)
and BP_DST_PA1 (backplane signal
connector)
2 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
3 SL3_CPU1_PA2 (signal connector on system
board)
CTRL_DST_PA1 (fPERC input connector)
140 Installing and removing system components