Figure 123. Configuration 47: 16 x 2.5-inch (8 x SAS/SATA with fPERC (H965i) + 8 x NVMe RAID with fPERC
(H965i))
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 126. 16 x 2.5-inch (8 x SAS/SATA with fPERC (H965i) + 8 x NVMe RAID with fPERC (H965i))
Order From To
1 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
2 SL3_CPU1_PA2 (signal connector on system
board)
CTRL_DST_PA1 (fPERC input connector)
3 SL4_CPU1_PB2 (signal connector on system
board)
CTRL_DST_PB1 (fPERC input connector)
4 CTRL_SRC_PA1 (fPERC controller connector) BP_DST_SA1 (backplane signal connector)
5 SIG_PWR_2 (system board power connector) BP_PWR_2 (backplane power connector)
6 CTRL_SRC_PB1 (fPERC controller connector) BP_DST_PA2 (backplane signal connector)
and BP_DST_PB2 (backplane signal
connector)
7 CTRL_SRC_PA1 (fPERC controller connector) BP_DST_PA1 (backplane signal connector)
and BP_DST_PB1 (backplane signal
connector)
8 SL7_CPU1_PB4 (signal connector on system
board)
CTRL_DST_PA1 (fPERC input connector)
9 SL8_CPU1_PA4 (signal connector on system
board)
CTRL_DST_PB1 (fPERC input connector)
NOTE: An 8 x 2.5-inch NVMe backplane with fPERC H965i should be assembled outside and inserted into the system,
along with all necessary cables.
Installing and removing system components 169