Table 32. Thermal restriction matrix for air cooled configuration (continued)
Configuratio
n
No
backp
lane
8 x 2.5-
inch
NVMe
16 x
2.5-
inch
SAS
16 x
2.5-
inch
NVMe
24 x 2.5-inch SAS
16 x
2.5-
inch
SAS
+ 8 x
2.5-
inch
NVMe
24 x
2.5-
inch
NVMe
12 x 3.5-inch
Ambie
nt
temper
ature
Rear storage
No
rear
drive
s
No rear
drives
No
rear
drive
s
No
rear
drive
s
No rear
drives
2 x
2.5-
inch
with
rear
fan
4 x
2.5-
inch
with
rear
fan
No
rear
drive
s
No
rear
drives
No
rear
drives
2.5-
inch
rear
drives
with
rear
fan
CPU
TDP/
cTDP
T-
Case
max
cente
r
(°C)
Fan
HPR GOLD fan
70%^
250 W 76 STD
fan
STD fan STD
fan
STD
fan
STD fan HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
GOLD
fan
HPR
GOLD
fan
HPR
GOLD
fan
35°C
(95°F)
270 W 71/75 HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
GOLD
fan
Require
d DLC
Require
d DLC
35°C
(95°F)
300 W 75/76
/81
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
GOLD
fan
Require
d DLC
Require
d DLC
35°C
(95°F)
350 W 79 HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
SLVR
fan
HPR
GOLD
fan*
Require
d DLC
Require
d DLC
35°C
(95°F)
350 W 57/66 Requir
ed
DLC
Require
d DLC
Requir
ed
DLC
Requir
ed
DLC
Require
d DLC
Require
d DLC
Require
d DLC
Requir
ed
DLC
Require
d DLC
Require
d DLC
Require
d DLC
35°C
(95°F)
NOTE: ^The fan speed in the 3.5-inch chassis is limited to 70% due to the drive dynamic profile.