49 PowerEdge R820 Technical Guide
See Fresh Air for relative humidity information
5% to 95% at a maximum wet bulb temperature of 33°C (91°F); atmosphere must be non-
condensing at all times
0.26 Grms at 5Hz to 350Hz in all orientations
1.87 Grms at 10Hz to 500Hz for 15 minutes (all six sides tested)
Half sine shock in all operational orientations of 31G +/– 5% with a pulse duration of 2.6ms
+/– 10%
Half sine shock on all six sides of 71G +/– 5% with a pulse duration of 2ms +/–10%; square
wave shock on all six sides of 27G with velocity change at 235 in/sec or greater
–15.2m to 3048m (–50 ft to 10,000 ft)
–15.2m to 12,000m (–50 ft to 39,370 ft)
Airborne contaminant level
Class G1 or lower as defined by ISA-S71.04-1985
Power supply specifications
Table 28 lists power supply specifications for the PowerEdge R820.
Table 28. Power supply specifications
Heat dissipation
(BTU/hr max)
1
Auto-ranging
2
Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55A per
power supply for 10ms or less.