a. Go to Chassis Overview.
The Chassis Health page is displayed.
b. The Storage capacity details, the Fault Tolerant Mode (Active/Passive), and Fault Tolerant
Status (Enabled) information is displayed on the right pane.
This fault-tolerance information is displayed only if the fault tolerant feature is enabled for the
storage components.
c. The lower section of chassis graphics provides the left view of the chassis. Point to the storage
component sub-graphic. The text hint provides additional information about the storage
component.
d. Click the storage component sub graphic to view the related information in the right pane.
21. To view the Status of the storage components, perform the following steps:
In the left pane, click Chassis Overview → Storage → Properties → Status.
The Storage Overview page displays the following information:
- Graphic summary of the physical disk drives installed in the chassis and their status.
- Summary of all the storage components with links to their respective pages.
- Used capacity and total capacity of the storage.
- Controller information.
Note: In case of a fault-tolerant controller, the name format is: Shared <PERC number> (Integrated
<number>).
For example, the active controller is Shared PERC 8 (Integrated 1) and the peer controller is Shared PERC
8 (Integrated 2).
- Recently logged storage events.
Note: For more information, see Online Help.
21 Upgrading PowerEdge VRTX to Support Shared Storage Expansion