Planning for Hyper-V: PowerVault™ MD3200 and MD3200i Series of Arrays 
 
  Page 7 
 
means that the storage array avoids network congestion with other non-storage traffic that is using the 
network. 
 
•  CHAP  
To have secure access between your host and storage array, enable target and mutual 
CHAP authentication on the hosts and storage arrays. Follow standard CHAP password 
guidelines for best security. Set a strong password that meets standard IT guidelines on 
all of the devices in your IP SAN. 
 
•  Virtual LAN (VLAN)  
If you want to physically isolate your IP SAN data traffic from general network traffic, 
use VLANs. Turn on VLAN tagging on the Dell PowerVault MD3200i storage array. A port 
can either transmit all tagged IP packets or all non-tagged IP packets. 
 
Note:  You must enable a VLAN throughout the entire iSCSI SAN from the network interface 
cards (NICs) and switches to the iSCSI ports; otherwise, behavior might be inconsistent. 
To simplify and avoid troubleshooting at deployment, make sure that the NICs, 
switches, and storage array are fully operational before you enable the VLAN feature 
for the entire solution. 
 
IP SAN Network Infrastructure for Performance 
This section describes some general implementation guidelines for performance. These guidelines 
might not apply to all applications. Review your application requirements prior to implementing these 
guidelines. 
 
General Network Practices 
Make sure the category rating for the cables used is gigabit-Ethernet-compliant (CAT5e or CAT6). 
Design your network to have the least amount of hops between the storage arrays and the servers. This 
design greatly reduces the failure points, it simplifies the manageability, and it reduces the latency 
and complexity of your network architecture (particularly in the area of redundancy).  
Use managed switches because they provide advance features to help you optimize and maintain your 
network for your application. Only use auto-negotiation because gigabit Ethernet networks are 
designed to always have auto-negotiation enabled. If a particular application requires a specific speed 
or duplex mode, you can accomplish this by changing the advertisement options of the switch.