What to do if DELLA 048-MS-T11512K cables or plugs are overheated?
- SStephanie JamesSep 5, 2025
If your DELLA Air Conditioner's cables or plugs are overheated, switch it off immediately and cut off the power supply.
What to do if DELLA 048-MS-T11512K cables or plugs are overheated?
If your DELLA Air Conditioner's cables or plugs are overheated, switch it off immediately and cut off the power supply.
Why DELLA Air Conditioner does not work?
Your DELLA Air Conditioner might not be working due to several reasons: - A power failure or not being properly plugged in. Check the power source and plug it in correctly. - A damaged indoor or outdoor unit fan motor. Inspect and replace the damaged fan motor. - A faulty compressor thermo-magnetic circuit breaker. Check and replace the faulty breaker. - Faulty protective devices or fuses. Inspect and replace any faulty fuses. - Loose connections. Secure all loose connections. - The self-protective feature may be active. Allow the appliance time to reset. - Voltage that is too high or too low. Check voltage levels and stabilize as needed. - An active timer-on function. Disable the timer function if it is not needed. - A damaged electronic control board. Replace the electronic control boar...
What does it mean when DELLA 048-MS-T11512K shows error code E6?
In case of malfunction of the indoor fan motor of your DELLA Air Conditioner, the display on the indoor unit shows error code E6 which flashes 6 times.
Why DELLA 048-MS-T11512K Air Conditioner has mist come out from the air outlet?
Mist coming from the air outlet of your DELLA Air Conditioner occurs when the air in the room becomes very cold, such as in the “cooling” or “dehumidifying / dry” modes.
Why DELLA Air Conditioner has running water noise?
If your DELLA Air Conditioner is making a running water noise, inspect the refrigerant circulation system, as this may be due to liquid black flow in the refrigerant circulation.
What does it mean when DELLA 048-MS-T11512K Air Conditioner shows error code E2?
In case of a faulty indoor pipe temperature sensor on your DELLA Air Conditioner, the display on the indoor unit shows error code E2 which flashes twice.
What does it mean when DELLA 048-MS-T11512K Air Conditioner shows error code E1?
In case of a faulty indoor temperature sensor on your DELLA Air Conditioner, the display on the indoor unit shows error code E1 which flashes once.
What to do if DELLA Air Conditioner has error signals on the display?
If your DELLA Air Conditioner is showing error signals on the display, switch it off immediately and cut off the power supply.
What to do if DELLA 048-MS-T11512K Air Conditioner has very strong smells?
If there are very strong smells coming from your DELLA Air Conditioner, switch it off immediately and cut off the power supply.
What to do if spraying water or objects inside DELLA Air Conditioner?
If there is spraying water or objects inside your DELLA Air Conditioner, switch it off immediately and cut off the power supply.
Guidelines for selecting the optimal location for the indoor unit installation.
Guidelines for selecting the optimal location for the outdoor unit installation.
Covers indoor unit pre-installation checks and mounting plate setup.
Details wall penetration for piping and indoor unit wiring procedures.
Steps for routing refrigerant pipes and connecting them to the indoor unit.
Instructions for drain hose setup and final indoor unit mounting.
Covers outdoor unit pre-installation and condensed water drainage setup.
Lists potential reasons for the appliance failing to operate.
Covers critical issues requiring shutdown and specific error codes displayed on the unit.