10
6. To eliminate residues of the solution and lime scale, rinse
the tank well and ll it with clean water (without des-
caler).
7. Rotate the selector dial to the position and operate
the appliance until the tank is completely empty;
8. Repeat operations 6 and 7 again.
Technical data
Mains voltage: ........................................ 220-240V~50/60Hz
Absorbed power: .........................................................1100W
Pressure: ....................................................................... 15 bar
Water tank capacity: ..................................................1.4 litres
Dimensions LxHxD .............................255x315x280 (395) mm
Weight ...........................................................................3.9 kg
The appliance is in compliance with the following
CE Directives:
      
amendments.
 -
ments.
 
with food stus are in compliance with the provisions of
the 1935/2004 European Standard.
None of the components of the appliance can
be washed in a dishwasher.
Problem Possible cause Solution
Espresso coee does not ow out No water in the tank Fill the water tank
The holes in the lter-holder are
blocked
Clean the holes in the lter-holder spouts
The espresso boiler outlet is blocked Clean as indicated in the “Cleaning the boiler
outlet” paragraph
Espresso coee drips from the ed-
ges of the lter-holder instead of
through the holes
The lter-holder is inserted incorrectly Attach the lter-holder correctly and turn it fully
home rmly
The espresso boiler gasket has lost
elasticity
Replace the espresso boiler gasket. Contact
De’Longhi Customer Experience
The holes in the lter-holder spout are
blocked
Clean the holes in the spouts
The espresso coee is cold The espresso OK light is not on when
the coee dial is rotated to coee
delivery
Wait for the OK light to switch on
Pre-heating has not been carried out Pre-heat as indicated in the paragraph “How to
Prepare Espresso Coee”
The cups have not been pre-heated Pre-heat the cups using hot water