9.3 MBU
51
60mm
closing force setting
+
/
-
Setting procedure (without capsule):
Step 1: Close the handle and give load to the setting screw
Preload of the system to compensate first creeping
Step 2: Open the handle
Step 3: Give load (11N) to the handle
Step 4: Drive setting screw slowly backwards until the handle closes completely.
Step 5: Repeat steps 1 to 4
Step 6: Control closing force by closing the handle with a spring balance
Closing force must be in the range of 13,5 2 N
13,5
2N
+/-
Clockwise = Increase closing force
Anticlockwise = Decrease closing force
_______________________________