23
Problem Cause Solution
The machine will not dispense any coee. Impurities have been detected in the inter-
nal circuits
Wait until the machine is ready for use again,
and proceed to select the required drink. Con-
tact customer services if the problem persists.
Coee does not come out of one or both
spouts.
Coee nozzles blocked. Clean the nozzles with a cloth. Any encrust-
ed deposits can be removed with a tooth-
pick, if necessary.
The coee delivered is watery. Pre-ground coee funnel clogged. Open the door and clean the funnel with
the aid of a brush.
The infuser cannot be extracted. The machine has not been correctly turned
o.
Turn the machine o by pressing the
button
.
With the descaling procedure completed,
the appliance prompts for a third rinse
During the two rinse cycles, the water tank
was not lled to the MAX level
Restart the descaling procedure from “Step 3:
Second rinse”.
The milk presents large bubbles or splashes
from the spout(E3) , or is under-frothed.
Milk is not cold enough, or is not semi-
skimmed or skimmed.
Use skimmed or semi-skimmed milk
straight from the refrigerator (tempera-
ture about 5° C). If the result is still not as
expected, try changing the brand of milk.
Milk carafe lid dirty. Disassemble the components and clean
thoroughly as described in section “9.7
Cleaning the milk carafe after each use”.
Take particular care when cleaning the milk
carafe connector (E6).
Vegetable drinks are being used.
The end-result varies widely depending on
the nutritional properties of the drinks. “Baris-
ta” versions of these drinks are recommended.
Milk-based drinks are not enabled Milk carafe missing or not correctly in place. Prepare the milk carafe and position it cor-
rectly in the machine.
Several milk drinks have been prepared in
succession and the machine needs to heat
up to the ideal temperature before making
the next drinks.
Wait until milk-based drinks are again ena-
bled on the control panel.
The cup tray on top of the machine is hot Several drinks have been prepared in rapid
succession
The machine emits noises or small pus of
steam while not in use
The machine is ready for use or has just
been turned o, and a few drops of con-
densate are falling into the steamer, which
is still hot.
This is to be expected as an aspect of normal
operation: to minimize the eect, empty
the drip tray regularly.
The machine emits pus of steam from the
drip tray and/or there is water on the sur-
face where the machine is positioned.
The drip tray grille has not been replaced
after cleaning.
Ensure the grille is repositioned in the drip
tray.
19. TECHNICAL DATA
Voltage: 220-240 V~ 50-60 Hz max. 10 A
Power: 1450 W
Pressure: 1.5 MPa (15 bars)
Water tank capacity: 1.8l
Size LxDxH: 240x440x360 mm
Cord length: 1250 mm
Weight (varies according to model): 9.6 kg
Beans container capacity: 250 g
De'Longhi reserves the right to modify the technical specication
and styling of its products at any moment, without compromis-
ing their functionality and quality.