8
Replace the cap correctly and close the tank, pu-
shingitinasfarasitwillgo.Thetankholehasa
meshltertopreventtheintroductionofforeign
matter.Ifnecessary,thisltercanbeunscrewed
and removed for cleaning under running water.
• Thetankdoesnothavetobefulltousethe
water function, but the length of time the
appliance will operate in water mode will be
shorter.
• Donotllabovetheleveloftheholetoavoid
thewateroverowing.Thetankhasnoover-
flow prevention system.
Replacing the limescale filter
Turn the appliance off and unplug it from the
outlet.
Makesurethereisnowaterintheapplianceby
emptying the tank and internal tray as described
inthesection:“Endofseasonoperations”.
Laytheapplianceonitsbackasshowningure
16. Rest it on a towel or piece of cardboard to
avoidscratchesordamage.Removethelterco-
verbyunscrewingthefourscrews(g.16).
Removethelterdelicatelyandloosenthetwo
ties, making sure the two hoses connecting the
lterdonotslipinsidetheappliance.Fitthenew
lter, following the same procedure in reverse
(g.16-17).Thenotchonthelter(seegure
15) indicates the correct direction. The notch
must always be towards the inside of the ap-
plianceandpoint“A”mustbefacingupwards.
Water may leak out while replacing the
limescale filter. You should therefore perform
the operation in a suitable location.
After replacing the filter, wait at least an hour
before starting the machine again.
When the filter has been replaced, turn the
alarm off by pressing the ON/STAND-BY
button (15) for 10 seconds.
The appliance emits a beep.
1
2
12
13
14
15