EasyManua.ls Logo

DELTA DORE TYMOOV radio RP2 Series - 1; Technical Characteristics; Table of Contents

DELTA DORE TYMOOV radio RP2 Series
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
6 7
Contents
• Power supply: 230V - 50 Hz +/- 10%
• Class II insulation
• Operating time: 4 minutes
• Electrical power :
TYMOOV 6RP2 / 6RE2 : 40 W
TYMOOV 10RP2 / 10RE2 / D10RP2 : 50 W
TYMOOV 20RP2 / 10RE2 / D20RP2 : 70 W
• X3D radio frequency: 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW Category 2 receiver
• Radio range: 100-300 metres in an open eld, variable depending on the
associated equipment (the range can vary depending on the installation conditions
and the electromagnetic environment)
• Number of associated transmitters: 16 maximum
A-weighted sound pressure level: LpA ≤ 70 dB(A).
• Degree of protection: IP 44
• Operating temperature: -20°C -> + 60°C
1/ Technical Characteristics
1/ Technical Characteristics ........................................................................7
2/ Motor tting .................................................................................................8
2.1 Crown and wheel assembly ................................................................................. 8
2.2 Assembly in the tube ............................................................................................... 8
2.3 Motor head position ........................................................................ ........................9
2.4 Attaching the motor to the mount .................................................................... 9
3/ Connection ................................................................................................10
3.1 Wiring without push button, only by transmitter .................................. 10
3.2 Wiring with a push button ................................................................................. 10
4/ Starting up for the rst time ...............................................................11
  ...................................... 11
4.2 Setting stops ........................................................................ ..................................... 12
5/ Modifying stops ......................................................................................16
6/ Associating another transmitter ....................................................... 16
7/ Linking a smoke detector directly to the motor ..........................17
8/ Grouped command ................................................................................. 17
9/ Obstacle detection .................................................................................18
9.1 Setting of the obstacle detection type ......................................................... 18
9.2 Adjustment of the sensitivity of obstacle detection
for Basic detection (only) ................................................................................... 19
10/ Remove one or several associations .............................................19
10.1 Remove the remote control association with the motor .................... 19
10.2 Remove all associations ...................................................................................... 19
11/ Favourite positions ..............................................................................20
12/ Association with an alarm control unit ........................................21
12.1 Associating Performance DxRP2 or xRP2 radio motor ...................... 21
 ................................................ 22
 ......................................................... 22
13/ Your remote control is lost or not functioning..........................23
13.1 From a new remote control .............................................................................. 23
13.2 From the push button .......................................................................................... 23
14/ Operation with a push button ........................................................23
15/ Setting stops from the push button (local control) .................24
15.1 Recording 2 automatic stops ........................................................................... 24
 ..................... 25
 ..................... 26
15.4 Recording 2 manual stops ................................................................................. 27
15.5 Removing stops ....................................................................................................... 28
16/ Factory reset .........................................................................................28
17/ Troubleshooting .................................................................................... 29