- Field of application: Wireless alarm equipment
- Radio range outside: 200 to 300 m depending on the environment
- Radio frequencies: 434 and 868 MHz bands, class I (standard EN300220)
- 9.9 GHz microwave detector (standard EN300400 / Use in France only)
- Temperature of use: -10°C to +55°C
- Nominal operating temperature: -5°C to +35°C
- Long term storage temperatures above 30°C may damage the operation of the batteries
- Nominal detection range: 12 meters (transversal movement)
- Angular width: 90°
- 7.2V power supply:Two LS14500 lithium batteries (supplied)
- Stand-by mode consumption: 80 µA
- Consumption for transmission: 20 mA
- Autonomy in normal operation: > 2 years
- Protection index: IP30 - IK02
- Use: dry interior only
- Self-surveillance of the unit: Tamper alarm in the case of opening
- Unit dimensions: 73 x 124 x 60 mm
- Weight (with 2 lithium batteries): 150 g
Because of changes in standards and equipment, the characteristics given in the text and
the illustrations in this document are not binding unless confirmed by Delta Dore.
7
TECHNICAL
CHARACTERISTICS
TYXAL
Wireless alarm range
Infrared and microwave
IRHX detector
Installation and User Guide
Test butto
n
Closing screw
Base
Detector
Lens
Installation at
a height of
2.2 to 2.4 m
from the floor
point of entry from outside
detector
installed at least
1 m from a convector
convecto
r
The IRHX detector is a detector that combi-
nes 2 movement detection technologies.
Its infrared (detects temperature) and micro-
wave (detects movement) technologies
make it highly immune to untimely detec-
tions by the infrared sensor.
This equipment analyses movement in its
detection zone and sends an alarm informa-
tion if an intrusion is detected.
The detection by the infrared sensor is
confirmed by the microwave detection.
The product is exclusively used for
indoor protection and is not recommen-
ded for the surveillance of a room with
large glass windows (veranda, etc.).
1
PRESENTATION
2
LOCATION
Installation precautions for detec-
ting intrusions correctly:
- The detector should preferably be positio-
ned in a corner.
- The detection field must be clear of any
obstacles (curtains, cupboard, etc.).
- The detector must not be pointed towards
an exterior point of entry (window),
- The detector must be installed at a height
of around 2.30 m from the floor,
- Prevent any source of moving heat near
the detector; do not place the detector in
front of a heat source (convector, chimney,
etc.).
- Place the detector at least 2 metres away
from a fluorescent light.
Contents
- a dual technology radio detector,
- installation and user Guide,
- two LS14500 lithium batteries (supplied),
- a packet of screws.
DELTA DORE
Bonnemain - 35270 COMBOURG - France
E-mail : deltadore@deltadore.com
Device complying with the requirements of the
R&TTE 1999/5/EC directives
*2701919_rev.1*
Question and Answer IconNeed help?

Do you have a question about the DELTA DORE TYXAL and is the answer not in the manual?

DELTA DORE TYXAL Specifications

General IconGeneral
BrandDELTA DORE
ModelTYXAL
CategorySmoke Alarm
LanguageEnglish

Summary

Presentation of the IRHX Detector

Product Usage Limitations

Exclusive indoor use; not for rooms with large glass windows like verandas.

Detector Location and Installation

Installation Precautions

Proper positioning, clear detection field, avoid heat sources and specific entry points.

Detector Mounting and Setup

Fitting and Changing Batteries

Instructions for installing and replacing the detector's lithium batteries.

Choosing Triggering Type

Selection between immediate or delayed alarm triggering upon presence detection.

Detector Learning and Testing

Learning Detector to Control Unit

Process for associating the detector with the control unit and partial operation.

Testing Detection Coverage

Procedure to validate the detector's detection area using the test button.