EasyManua.ls Logo

Delta Electronics AC Motor Drive VFD007S23A - Page 63

Delta Electronics AC Motor Drive VFD007S23A
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Parameters|VFD-S Series
5-8 Revision August 2006, SE08, SW V2.61
Pr. Explanation Settings
Factory
Setting
NOTE
6-05 Over-Torque Detection Time d0.1 to d10.0 Sec d0.1
6-06
Electronic Thermal Overload Relay
Selection
d0 to d2 d2
6-07
Electronic Thermal
Characteristic
d30 to d600 Sec d60
d0: No fault
d1: Over current (oc)
d2: Over voltage (ov)
d3: Over heat (oH)
6-08
Present Fault Record
d4: Over load (oL)
d5: Over load (oL1)
d6: External fault (EF)
6-09 Second Most Recent Fault Record
d7: Reserved
d8: Reserved
d9: Excess current during
acceleration (ocA)
d10: Excess current during
deceleration (ocd)
d11: Excess current during steady
state (ocn)
6-10 Third Most Recent Fault Record
d12: Ground fault (GF)
d0
d13: Reserved
d14: Low voltage (Lv)
d15: CPU failure 1 (cF1)
d16: CPU failure 2 (cF2)
d17: Base block (b.b.)
d18: Overload (oL2)
d19: Auto acceleration/deceleration
failure (cFA)
d20: Software protection enable
(codE)
d21: Reserved
d22: CPU failure (cF3.1)
d23: CPU failure (cF3.2)
d24: CPU failure (cF3.3)
d25: CPU failure (cF3.4)
d26: CPU failure (cF3.5)
d27: CPU failure (cF3.6)
d28: CPU failure (cF3.7)
d29: Hardware protection failure
(HPF.1)
d30: Hardware protection failure
(HPF.2)
d31: Hardware protection failure
(HPF.3)
d32: Communication time-out
(CE10)
d33: Reserved
d34: Software error (SErr)
d35: Reserved
d36: PID error (Pld)
d37: Reserved
d38: Phase loss (PHL)
d0

Table of Contents

Related product manuals