Charger Fault Codes
Code
Solution
F-0-0-1, F-0-0-2
F-0-0-3, F-0-0-4
F-0-0-6
Internal charger fault. Remove AC and battery for minimum 30 seconds and retry
charger. If it fails again, please contact the manufacturer of your vehicle or machine.
Visit www.youtube.com/deltaqtechnologies for instructional videos.
Charger Error Codes
Code
Description
Solution
E-0-0-1
E-0-4-7
Battery high voltage
Check the battery voltage and cable connections. Check battery size
and condition. This error will clear once the condition has been
corrected.
E-0-0-4
BMS or battery fault
detected
Refer to unit’s operator manual.
E-0-0-7
Battery amp hour limit
exceeded
Possible causes include poor battery health, very deeply discharged
battery, poorly connected battery, and / or high parasitic loads on
battery while charging. Possible solutions: Replace battery pack.
Check DC connections. Disconnect parasitic loads. This error will
clear once the charger is reset by cycling DC.
E-0-1-2
Reverse polarity error
Battery is connected to the charger incorrectly. Check the battery
connections. This error will clear once the condition has been
corrected.
E-0-3-7
Re-programming failed
Software upgrade failure or script operation failure. Check new
software is correct.
E-0-2-3
High AC voltage error
(>270VAC)
Connect charger to an AC source that provides stable AC between 85-
270 VAC/45-65 Hz. This error will clear once the condition has been
corrected.
E-0-2-4
Charger failed to initialize
The charger has failed to turn on properly. Disconnect AC input and
battery for 30 seconds before retrying.
E-0-2-5
Low AC voltage/ oscillation
error
AC source is unstable. Could be caused by undersized generator
and/or severely undersized input cables. Connect charger to an AC
source that provides stable AC between 85-270 VAC/45-65 Hz. This
error will clear once the condition has been corrected.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta-q EXIDE ACH027M24101 and is the answer not in the manual?

Delta-q EXIDE ACH027M24101 Specifications

General IconGeneral
BrandDelta-q
ModelEXIDE ACH027M24101
CategoryBattery Charger
LanguageEnglish

Related product manuals