EasyManua.ls Logo

Delta AC MAX Smart - Technical Specifications; Charging and Electrical Specifications; Environmental and Physical Specifications

Delta AC MAX Smart
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
AC_MAX_SMART_QIG_EU_V1.0.0_2021-03
Version Smart
Charging mode Mode 3
Charging interface
IEC 62196-2: Type 1 plug, Type 2 plug, Type 2
socket, or Type 2 socket with shutter
Input/output rating
220-240 V
AC
, 1~, 16 A or 32 A max., 50-60 Hz
380-415 V
AC
, 3~, 16 A or 32 A max., 50-60 Hz
Input wiring
Single-phase: L1, N, PE
Three-phase: L1, L2, L3, N, PE/ L1, L2, L3, PE (IT)
Standby power < 5,0 W*
Altitude 2000 m
Internal residual current detection AC 30 mA, DC 6 mA
Surge protection Class II
Electrical protection
Over current protection, short circuit protection,
over voltage protection, under voltage protection,
ground fault protection, surge protection, over
temperature protection
Cold load pick-up
Randomized delay between 5 and 100 seconds
before the charge resume after power outages.
Status indicators Blue, green, red, yellow
Network interface Bluetooth, ethernet, wi, cellular
Charging protocol OCPP 1.6J
Card reader RFID card reader compliant to ISO/IEC 14443 A/B
Operating temperature -30ºC to +50ºC (-22ºF to +122ºF)
Storage temperature -40ºC to +80ºC (-40ºF to +176ºF)
Relative humidity < 95%, non-condensing
Length of charging cable 5 m, straight cable
Ingress protection IP55
Impact protection IK09
Cooling Natural cooling
Dimension (H x W x D)
371 x 218 x 167 mm (14.6 x 8.6 x 6.6 inch), exclu-
ding charging cable, mounting bracket and cable
holder
Net weight
3.9 kg*
Compliance/ certicate CE, UKCA
* Depends on model conguration.