INSTALLATION AND OPERATING INSTRUCTIONS
CEILING/WALL VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Make sure that the electric service supply voltage is AC
120V, 60Hz.
2. Follow all local electrical and safety codes, as well as
the National Electrical Code (NEC) and the Occupation
al Safety and Healthy Act (OSHAct).
3. Always disconnect the power source before working
on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease,
hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are congured as
shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
1. For General Ventilating Use Only. Do Not Use To
Exhaust Hazardous Or Explosive Materials And Vapors.
2. Not for use in cooking area. (Fig. B)
3. This product must properly connect to the grounding
conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan at
least 8.2 feet (2.5m) above the oor.
1. Single Speed Model: ITG80
Single speed control mode: Turn the power switch to
operate ON/OFF.
1. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
2. Before servicing or cleaning the unit, switch power o
at service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualied person(s) in accordance with all applicable
codes and standards, including re-rated construction.
4. Sucient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of fuel
burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guideline and
safety standards such as those published by the National
Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application and
be connected to a GFCI (Ground Fault Circuit
Interrupter) – protected branch circuit.
8. Do not use this unit with any other solid-state control
device. Solid-state controls devices may cause harmonic
distortion, which can cause a motor humming noise.
9. NEVER place a switch where it can be reached from a
tub or shower.
10. Not to be installed in a ceiling thermally insulated to a
value greater than R40. (This is required for installation
in Canada only).
CAUTION
SUPPLIED ACCESSORIES
Part name
Appearance Quantity
Grille
1
Fan
1
Housing
1
4” Duct
1
Screw
(M4x12)
3
45
o
Cooking area
45
o
Do not install above or
inside this area
Cooking
Equipment
floor
Fig. B
DIMENSIONS
SPECIFICATIONS
Note: Design and specications are subject to change
without notice.
Operation
MAINTENANCE WARNING:
Disconnect the power source before working on the
unit. Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any
other such chemicals for cleaning the
ventilating fan.
2. Do not allow water to enter the motor.
3. Do not soak resin parts in water over 60°C (140
o
F).
CLEANING
1.
Pull down the spring to remove the grille.
2. Wash and clean the grille. (Use non-abrasive
kitchen detergent and wipe dry with a new
cloth.)
3. Remove dust and dirt from the ventilating fan
using a vacuum cleaner.
4. Using a cloth dampened with kitchen detergent,
remove any dirt from the ventilating fan. Wipe
dry with a new cloth.
5. Replace the grille.
Model No.
Voltage
(V)
Frequency
(Hz)
Power
(W)
Air Flow
@ 0.1SP
(CFM)
Weight
(lb.)
Note
ITG80
120
60 12
80
4.0
Single
Speed
Turning angle too large Duct shrink
Too many elbows
Elbow near the body
Body
Fig. A
Page 1.
MODEL: ITG80
5.75
Question and Answer IconNeed help?

Do you have a question about the Delta breez Integrity ITG80 and is the answer not in the manual?

Summary

INSTALLATION AND OPERATING INSTRUCTIONS

GENERAL SAFETY INFORMATION

Essential safety guidelines for electrical connections and installation procedures.

WARNING

Critical warnings to reduce risks of fire, electric shock, or injury during use.

CAUTION

Important notes for proper use, installation, and avoiding hazards.

DIMENSIONS

Physical dimensions of the ventilation fan unit.

SPECIFICATIONS

Technical specifications including model, power, airflow, and weight.

Operation

Instructions for operating the single-speed ventilation fan.

MAINTENANCE WARNING

Crucial warnings to observe before performing maintenance on the unit.

CLEANING

Step-by-step guide for cleaning the ventilation fan components.

SUPPLIED ACCESSORIES

List of parts included with the ventilation fan for installation.

INSTALLATIONS

Install with wood frame

Specifications for installation using a wood frame, including dimensions.

WARRANTY

Information regarding the three-year limited warranty for ventilation fans.

Limitations and Exclusions

Details on what the warranty covers and its limitations, including exclusions.

Overview

The Delta Breez Integrity ITG80 is a single-speed ceiling/wall ventilation fan designed for general ventilating use in residential settings. It is specifically UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit, making it suitable for high-humidity environments like bathrooms. The fan operates on a standard AC 120V, 60Hz power supply and has a power consumption of 12 Watts. It delivers an airflow of 80 CFM (Cubic Feet per Minute) at 0.1 SP (Static Pressure), ensuring effective air circulation and moisture removal. The unit weighs 4.0 lbs, making it relatively lightweight for installation. Its compact dimensions are 10.7 inches in length, 9.4 inches in width, and 5.75 inches in depth, with an installation dimension of 7.5 x 7.25 inches.

Function Description:

The primary function of the ITG80 is to exhaust stale air, moisture, and odors from indoor spaces, contributing to improved indoor air quality and preventing mold and mildew growth. It is designed for general ventilation and should not be used to exhaust hazardous or explosive materials and vapors, nor is it intended for use in cooking areas. The fan operates with a simple ON/OFF control via a power switch. Proper installation requires a 4-inch circular duct, and the manual emphasizes using the shortest, straightest duct routing possible for optimal performance, airflow, noise reduction, and energy efficiency. Insulation around the ducts is recommended to reduce energy loss and inhibit mold growth.

Important Technical Specifications:

  • Model: ITG80
  • Voltage: 120V AC
  • Frequency: 60Hz
  • Power Consumption: 12 Watts
  • Airflow: 80 CFM @ 0.1 SP
  • Weight: 4.0 lbs
  • Installation Dimensions: 7.5 x 7.25 inches
  • Overall Dimensions: 10.7" (L) x 9.4" (W) x 5.75" (D)
  • Duct Size: 4-inch circular
  • Speed: Single Speed
  • UL Listed: For use over bathtub or shower when installed in a GFCI protected branch circuit.
  • Minimum Installation Height: 8.2 feet (2.5m) above the floor.

Usage Features:

The ITG80 is designed for straightforward operation. Once installed and connected to a power source, it can be turned ON or OFF using a standard wall switch. The manual provides detailed installation instructions for both new construction (prior to finishing the ceiling) and replacement installations in existing ceilings. It also includes guidance for installing in an existing ceiling by bending tabs outward to rest against joists or studs. The fan is supplied with essential accessories including the grille, fan body, housing, a 4-inch duct connector, and screws for assembly. The design emphasizes ease of installation with clear steps for wiring, duct connection, and securing the housing. It is crucial to ensure proper grounding of the supply circuit for safety. The manual strictly advises against installing the unit where ducts are configured with excessive bends or sharp angles, as this can impede performance. It also warns against installing the fan in thermally insulated ceilings with a value greater than R40 (required for Canada only).

Maintenance Features:

Routine maintenance is crucial for the longevity and efficient operation of the ITG80. The manual recommends performing maintenance annually and emphasizes disconnecting the power source before any servicing or cleaning.

  • Cleaning the Grille: The grille can be easily removed by pulling down its springs. It should be washed and cleaned using a non-abrasive kitchen detergent and then wiped dry with a new cloth.
  • Cleaning the Fan Body: Dust and dirt can be removed from the ventilating fan using a vacuum cleaner. For more thorough cleaning, a cloth dampened with kitchen detergent can be used to wipe away dirt, followed by wiping dry with a new cloth.
  • Important Maintenance Cautions:
    • Never use gasoline, benzene, thinner, or any other harsh chemicals for cleaning the fan.
    • Prevent water from entering the motor.
    • Do not soak resin parts in water over 60°C (140°F).

The Delta Breez Integrity ITG80 comes with a three-year limited warranty from Delta Electronics Inc. for the original consumer purchaser in the USA and Canada, covering defects in material and workmanship. The warranty specifically excludes charges for labor or other costs incurred during troubleshooting, repair, removal, and installation service. It also does not cover damage caused by abuse, misuse, improper installation, or failure to comply with the manufacturer's installation manual.