Chapter 3 Parallel Application Introductions Parallel Control Solution
20
3-1 Parameter Overview
The following describes the parameters related to parallel connection:
You can set this parameter during operation
00-62
Six-Phase Motor Master and Slave Settings
Default: 0
Settings
0–2
0: Single unit mode
1: Master mode
2: Slave mode
00-63
Optical Fiber Communication Card Software Version
Default: Read only
Settings
Read only
Displays the current software version of the optical fiber communication card.
00-65
Six-Phase Motor Coil Offset Angle
Default: 0
Settings
-360.0360.0
Depending on the design considerations of the six-phase motor winding, the two windings may
need to be electrically offset. Common offset angles are 0 degrees, 30 degrees, and 60 degrees.
In the control architecture, the main control output voltage is typically adjusted by 30 degrees
based on the motor structure before output. However, due to possible process or structural
errors, the offset angle parameter can be fine-tuned to ensure consistency between the master
and slave controls.