15
Figure 7: Location of type label
E6-TL-US
DC Max. System Voltage:
DC Operating Voltage Range:
DC Full Power MPPT Range:
DC Max. Input Current per String:
AC Nominal Output Voltage:
AC Operating Voltage Range:
AC Max. Continuous Output Current:
AC Max. Continuous Output Power:
AC Nominal Output Frequency:
AC Operating Frequency Range:
Output Power Factor:
This device complies with part 15 of FCC rules.
Operation is subject to the following two conditions:
(1)this device may not cause harmful interference,and
(2)this device must accept any interference received,
including interference that may cause undesired operation.
GPI60210033P
Rev.:XX
Date Code:YYWW
S/N:MMMYYWWRRZZZZ
Made in China
240436
480 V
50-480 V
200-480 V
12 A
60 Hz
59.3-60.5 Hz
0.99(0.85i-0.85c adj.)
Type 1
208 V
183-228 V
24 A
5472 W
240 V
211-264 V
24 A
6000 W
Enclosure Type: Type 4
Grid Support Utility-Interactive Transformerless Inverter
Ambient Temperature: -30 - +65°C Derating >45°C
CSA C22.2 NO.107.1-01 UL1741 UL1699B
Battery DC Max.Input/output Voltage:
Battery DC Operating Voltage Range:
Battery DC Max.Input/output Current:
480 V
350-480 V
15 A
5min
E8-TL-US
This device complies with part 15 of FCC rules.
Operation is subject to the following two conditions:
(1)this device may not cause harmful interference,and
(2)this device must accept any interference received,
including interference that may cause undesired operation.
GPI76210034P
Rev.:XX
Date Code:YYWW
S/N:MMMYYWWRRZZZZ
Made in China
240436
Type 1
Enclosure Type: Type 4
Grid Support Utility-Interactive Transformerless Inverter
Ambient Temperature: -30 - +65°C Derating >45°C
CSA C22.2 NO.107.1-01 UL1741 UL1699B
480 V
50-480 V
270-480 V
12 A
60 Hz
59.3-60.5 Hz
0.99(0.85i-0.85c adj.)
PV DC Max System Voltage:
PV DC Operating Voltage Range:
PV DC Full Power MPPT Range:
PV DC Max. Input Current per String:
AC Nominal Output Voltage:
AC Operating Voltage Range:
AC Max. Continuous Output Current:
AC Max. Continuous Output Power:
AC Nominal Output Frequency:
AC Operating Frequency Range:
Output Power Factor:
208 V
183-228 V
32 A
7296 W
240 V
211-264 V
32 A
8000 W
Battery DC Max.Input/output Voltage:
Battery DC Operating Voltage Range:
Battery DC Max.Input/output Current:
480 V
350-480 V
15 A
5min
WARNING
AVERTISSEMENT
*Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
*Risk of electric shock. Do not remove or destroy this label.
*Do not remove the cover. No user serviceable parts inside. Refer servicing to
qualified service personnel.
*Both AC and DC voltage sources are terminated inside this equipment.
Disconnect each circuit individually before servicing.
*When the photovoltaic array is exposed to light, it supplies DC voltage to the
equipment.
*Risk of e
lectric shock from energy stored in capacitor. Do not remove cover until 5
minutes after disconnection all sources of supply.
*Normally grounded conductors may be ungrounded and energized when a ground
fault is indicated.
*Voltage and frequency trip points are factory set to current UL1741.2 and IEEE
1547/1547.1 standards.
*Warning: More than one live circuit. See diagram in manual.
*Hot surfaces. To reduce the r
isk of burns, do not touch.
*Cancer et effet nocif sur la reproduction -
www.P65Warnings.ca.gov.
*Risque de choc électrique,ne pas enlever ou détruire cette étiquette.
*Pour le raccordement voir le manuel.
*Le boîtier ne doit en aucun cas
ê
tre ouvert.Aucun composant interne n´est à
entretenir.Reportez-vous à un technicien qualifé pour tout entretien.
*Les deux sources de tension CA et CC sont résiliées à
l`
intérieur de cet
équipement.Débranchez chaque circuit individuel avant tout entretien.
*Quand les panneaux photovoltaïque sont expos
és à
la lumière,ils fournissent une
tension en courant continu à l
´é
quipement.
*Risque de choc
é
lectrique à partir d
´é
nergie stockée dans les
condensateurs.Retirer le couvercle du boîtier au moin 5 minutes après avoir
d
ébranché toutes les sources d´approvisionement.
*Attention:
Risque de choc
é
lectrique.Les conducteurs DC de ce système
photovoltaïque ne sont pas fondées et peuvent être alimentés.
Attention:Risque de choc
é
lectrique.Les conducteurs DC de ce système
photovoltaïque ne sont normalement mis à la terre,mais deviendra intermittence
terre sans indication lorsque le variateur mesure le photovoltaïque isolement.
*Surface chaude.Pour réduire le risque de br
ûlures ne pas toucher.