50
5.1.3  LED Message
The LEDs indicate the operational status of the inverter 
Message 
Category 
LED Signals  Message Explanation  Example 
LED  Color Status  Behavior 
Operation 
Normal 
operation 
OPER  Green  <ON> Constant on  The inverter feeds in grid. 
Sync. OPER Green  <BAR> Four LEDs  form 
a progress bar. 
The inverter is synchronizing with 
grid. 
LED signals: 
OPER LED is ON, 
BAT LED is ON. 
COMM LED Blinks 
Message: 
is 50%-75%. 
BAT  Green  <BAR> 
COMM  Green  <BAR> 
INFO  Green  <BAR> 
Night mode OPER  Green  <BLINK>  1s on, 4s off  Grid is connected, but the inverter 
is unable to feed in grid because 
PV voltage is too low. 
Battery 
Battery fault BAT  Red  <ON> Constant on  Battery is in fault mode. 
Battery 
comm. fail 
BAT Yellow <ON> Constant on Battery communication timeout 
Battery 
standby 
BAT  Yellow <BLINK>  1s on, 1s off  Battery is in standby mode 
power 
BAT  Green <BLINK>  1s on, 4s off 
Absolute battery power is lower 
than 50W 
Battery 
normal 
BAT  Green  <ON> Constant on  Battery is in normal operation. 
Communication 
BLE fail  COMM Red  <ON> Constant on  BLE is in fault mode 
APP 
Connected 
COMM  Green <ON> Constant on APP is connected 
running 
COMM  Green  <BLINK>  1s on, 1s off  BLE is running  Only  BLINK for 2 cycles in 
one minute 
Information 
Firmware 
upgrading 
INFO  Yellow  <BLINK>  1s on, 1s off  Firmware upgrading is ongoing 
Receiving 
image 
INFO  Green  <BLINK>  1s on, 1s off  Inverter is receiving image file 
Equipment 
alarm 
INFO  Yellow <ON>  Constant on  External event occurs and inverter 
is unable to run 
Fault 
Arc fault  FAULT  Red  <ON> Constant on  Arc fault occurs 
Ground fault FAULT  Red  <BLINK>  1s on, 1s off  Ground fault occurs 
Other 
Initialization OPER  Green  <ON> On until done I
nverter initialization when grid is 
changing from disconnected  into 
connected. 
BAT  Green  <ON> On until done 
COMM  Green  <ON> On until done 